Standoff determination of the particle size and concentration of small optical depth clouds based on double-scattering measurements: validation with calibrated target plates and limitations for daytime and nighttime measurements

Nathalie Roy,Gilles Roy
DOI: https://doi.org/10.1364/ao.47.004235
2008-08-10
Abstract:Diffractive target plates are used to emulate aerosols of known size and concentration. These target plates are used to validate and determine the sensitivity of a multiple-field-of-view lidar signal inversion technique based on double-scattering measurement to retrieve the particle size and the concentration of small optical depth clouds. We estimate that nighttime and daytime quantification (size and concentration) is possible for optical depths as low as 0.005 and 0.016, respectively. The recovery technique limiting factors are the shot noise, the laser features, the optical lens quality, the background illumination level, the background aerosol fluctuations, and the noise introduced by the lidar detector, a gated intensified camera (camera G-ICCD).
What problem does this paper attempt to address?