Spontaneous anti-Stokes Raman probe for gas temperature measurements in industrial furnaces

G Zikratov,F Y Yueh,J P Singh,O P Norton,R A Kumar,R L Cook
DOI: https://doi.org/10.1364/ao.38.001467
1999-03-20
Abstract:A compact, pulsed Nd:YAG laser-based instrument has been built to measure in situ absolute gas temperatures in large industrial furnaces by use of spontaneous anti-Stokes Raman scattering. The backscattering configuration was used to simplify the optics alignment and increase signal-to-noise ratios. Gated signal detection significantly reduced the background emission that is found in combustion environments. The anti-Stokes instead of the Stokes component was used to eliminate contributions to spectra from cold atmospheric nitrogen. The system was evaluated in a methane/air flame and in a bench-top oven, and the technique was found to be a reliable tool for nonintrusive absolute temperature measurements with relatively clean gas streams. A water-cooled insertion probe was integrated with the Raman system for measurement of the temperature profiles inside an industrial furnace. Gas temperatures near 1500-1800 K at atmospheric pressure in an industrial furnace were inferred by fitting calculated profiles to experimental spectra with a standard deviation of less than 1% for averaging times of approximately 200 s. The temperatures inferred from Raman spectra are in good agreement with data recorded with a thermocouple probe.
What problem does this paper attempt to address?