Quantum plasmonic sensing using single photons

Joong-Sung Lee,Seung-Jin Yoon,Hyungju Rah,Mark Tame,Carsten Rockstuhl,Seok Ho Song,Changhyoup Lee,Kwang-Geol Lee
DOI: https://doi.org/10.1364/OE.26.029272
2018-10-26
Abstract:Reducing the noise below the shot-noise limit in sensing devices is one of the key promises of quantum technologies. Here, we study quantum plasmonic sensing based on an attenuated total reflection configuration with single photons as input. Our sensor is the Kretschmann configuration with a gold film, and a blood protein in an aqueous solution with different concentrations serves as an analyte. The estimation of the refractive index is performed using heralded single photons. We also determine the estimation error from a statistical analysis over a number of repetitions of identical and independent experiments. We show that the errors of our plasmonic sensor with single photons are below the shot-noise limit even in the presence of various experimental imperfections. Our results demonstrate a practical application of quantum plasmonic sensing is possible given certain improvements are made to the setup investigated, and pave the way for a future generation of quantum plasmonic applications based on similar techniques.
Quantum Physics,Optics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to reduce the noise in sensing devices to below the shot - noise limit (SNL). Specifically, the researchers explored the quantum plasmonic sensing technology using single photons as input signals to achieve this goal through the Kretschmann configuration of attenuated total reflection. The sensor used in the paper is the Kretschmann configuration based on a gold film, and aqueous solutions of blood proteins with different concentrations were used as analytes in the experiment. The main purpose of the study was to evaluate the error in estimating the refractive index using single photons and compare it with the error generated by a classical laser source, in order to show that quantum plasmonic sensing has the potential to surpass traditional techniques after specific improvements. ### Key Point Summary: 1. **Research Background**: - Plasmonic effects have been successfully applied in practical photonic sensors, providing higher sensitivity than traditional photonic sensing platforms. - The Kretschmann configuration is the most widely used plasmonic sensor, and its simplicity has led to great success in commercialized classical biosensing. 2. **Research Purposes**: - Using single photons as input signals, study the performance of quantum plasmonic sensing in the attenuated total - reflection configuration. - Evaluate the error in estimating the refractive index using single photons and compare it with the error generated by a classical laser source. - Demonstrate that the error of quantum plasmonic sensing can still be below the shot - noise limit even in the presence of various experimental imperfections. 3. **Experimental Methods**: - The experimental setup includes a continuous - wave diode laser, which generates a pair of orthogonally polarized photons through a nonlinear crystal. - Use a single - photon detector to detect one of the pair of photons (idler), thereby verifying the existence of the other photon (signal). - Calculate the total transmittance and its standard deviation by measuring the number of transmitted photons at different angles, and then evaluate the error in estimating the refractive index. 4. **Results and Discussions**: - The experimental results show that the quantum plasmonic sensing using single photons can achieve an error below the shot - noise limit at different total transmittances. - By fixing the incident angle and changing the blood protein concentration, the sensitivity and accuracy of the sensor were further verified. - The paper also discussed how to systematically improve the experimental setup to further enhance the quantum enhancement effect. ### Formula Summary: - **Reflectivity Formula**: \[ R_{\text{sp}}=\left|\frac{e^{i2k_2d}r_{23}+r_{12}}{e^{i2k_2d}r_{23}-r_{12}}\right|^2 \] where \(r_{lm}=\frac{k_l\sqrt{\epsilon_l}-k_m\sqrt{\epsilon_m}}{k_l\sqrt{\epsilon_l}+k_m\sqrt{\epsilon_m}}\), \(k_l\) is the wave vector component perpendicular to the surface of the \(l\) - th layer, \(\epsilon_l\) is the corresponding dielectric constant, and \(d\) is the thickness of the second layer. - **Normalized Transmittance**: \[ T_{\text{prism}}=\frac{T_{\text{total}}}{\langle T_{\text{total, air}}\rangle} \] - **Standard Deviations of Classical and Quantum Sensing**: \[ \Delta T_{\text{total}}^{\text{(C)}}=\sqrt{\frac{T_{\text{true}}^{\text{(total)}}}{\nu}} \] \[ \Delta T_{\text{total}}^{\text{(Q)}}=\sqrt{\frac{T_{\text{true}}^{\text{(total)}}(1 - T_{\t