Pro-arrhythmogenic effects of heterogeneous tissue curvature: A suggestion for role of left atrial appendage in atrial fibrillation

Jun-Seop Song,Jaehyeok Kim,Byounghyun Lim,Young-Seon Lee,Minki Hwang,Boyoung Joung,Eun Bo Shim,Hui-Nam Pak
DOI: https://doi.org/10.1253/circj.CJ-18-0615
2018-09-14
Abstract:Background: The arrhythmogenic role of atrial complex morphology has not yet been clearly elucidated. We hypothesized that bumpy tissue geometry can induce action potential duration (APD) dispersion and wavebreak in atrial fibrillation (AF). Methods and Results: We simulated 2D-bumpy atrial model by varying the degree of bumpiness, and 3D-left atrial (LA) models integrated by LA computed tomographic (CT) images taken from 14 patients with persistent AF. We also analyzed wave-dynamic parameters with bipolar electrograms during AF and compared them with LA-CT geometry in 30 patients with persistent AF. In 2D-bumpy model, APD dispersion increased (p<0.001) and wavebreak occurred spontaneously when the surface bumpiness was higher, showing phase transition-like behavior (p<0.001). Bumpiness gradient 2D-model showed that spiral wave drifted in the direction of higher bumpiness, and phase singularity (PS) points were mostly located in areas with higher bumpiness. In 3D-LA model, PS density was higher in LA appendage (LAA) compared to other LA parts (p<0.05). In 30 persistent AF patients, the surface bumpiness of LAA was 5.8-times that of other LA parts (p<0.001), and exceeded critical bumpiness to induce wavebreak. Wave dynamics complexity parameters were consistently dominant in LAA (p<0.001). Conclusion: The bumpy tissue geometry promotes APD dispersion, wavebreak, and spiral wave drift in in silico human atrial tissue, and corresponds to clinical electro-anatomical maps.
Tissues and Organs,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: the role of the complex morphology of the atrium in arrhythmia has not been fully elucidated. Specifically, the researchers hypothesized that irregular tissue geometries can cause dispersion of action potential duration (APD) and wavebreak, thereby promoting the occurrence and development of atrial fibrillation (AF). The main objective of the study was to verify this hypothesis through simulation and clinical data analysis and to explore the potential arrhythmogenic role of the left atrial appendage (LAA) in AF maintenance. ### Research Background and Hypothesis - **Background**: Atrial fibrillation (AF) is one of the most common arrhythmias and increases the risk of cardiogenic stroke and death. Although pulmonary vein isolation (PVI) is an effective treatment for AF, in patients with persistent AF, PVI alone may not be sufficient to control the condition. - **Hypothesis**: The researchers hypothesized that irregular tissue geometries (such as the complex convex structures of the left atrial appendage) can lead to APD dispersion and wavebreak, thereby promoting the occurrence and development of AF. ### Research Methods 1. **2D Irregular Surface Model**: - Simulate 2D irregular atrial models with different degrees of convexity. - Analyze the dispersion of APD and the occurrence of wavebreak. 2. **3D Left Atrial Model**: - Use CT images of 14 patients with persistent AF to construct 3D left atrial models. - Simulate AF and analyze the density of phase singularities (PS). 3. **Clinical Data**: - Analyze the bipolar electrogram signals of 30 patients with persistent AF and calculate parameters such as CFAE cycle length (CFAE - CL), Shannon entropy (ShEn), and approximate entropy (ApEn). - Compare the surface convexity and wave dynamics parameters of the left atrial appendage (LAA) with those of other left atrial parts. ### Main Findings - **2D Model**: - The degree of APD dispersion on the irregular surface increases with the increase in convexity. - High - convex surfaces spontaneously generate wavebreak, showing behavior similar to phase transition. - Spiral waves tend to drift towards regions with higher convexity. - **3D Model**: - The surface convexity of the left atrial appendage (LAA) is significantly higher than that of other left atrial parts. - The PS density in the LAA is significantly higher than that of other left atrial parts. - **Clinical Data**: - The surface convexity of the LAA is 5.8 times that of other left atrial parts. - The CFAE - CL in the LAA is lower, and the proportion of CFAE areas is higher. - The ShEn and ApEn values in the LAA are higher, indicating more complex wave dynamics parameters. ### Conclusions - **Conclusion**: Irregular tissue geometries can promote APD dispersion, wavebreak, and spiral wave drift, which has been verified in computer - simulated human atrial tissue and is consistent with clinical electrophysiological maps. The complex convex structure of the left atrial appendage (LAA) may be an important arrhythmogenic factor in AF maintenance. ### Clinical Significance - **Significance**: Although much clinical evidence supports the effectiveness of LAA isolation in controlling AF, the mechanism of the LAA in AF maintenance has not been fully revealed. This study proposes a potential mechanism, that is, the complex convex structure of the LAA may play an important role in the arrhythmogenesis of AF. Therefore, not only assessing tissue heterogeneity but also measuring surface convexity may help to more accurately locate the target area for ablation surgery.