Quantifying the intrinsic surface charge density and charge-transfer resistance of the graphene-solution interface through bias-free low-level charge measurement

Jinglei Ping,A. T. Charlie Johnson
DOI: https://doi.org/10.1063/1.4955404
2017-08-30
Abstract:Liquid-based bio-applications of graphene require a quantitative understanding of the graphene-liquid interface, with the surface charge density of adsorbed ions, the interfacial charge transfer resistance, and the interfacial charge noise being of particular importance. We quantified these properties through measurements of the zero-bias Faradaic charge-transfer between graphene electrodes and aqueous solutions of varying ionic strength using a reproducible, low-noise, minimally perturbative charge measurement technique. The measurements indicated that adsorbed ions had a negative surface charge density of approximately -32.8 mC m-2 and that the specific charge transfer resistance was 6.5pm0.3 M${\Omega}$ cm2. The normalized current noise power spectral density for all ionic concentrations tested collapsed onto a 1/f characteristic with ${\alpha}$=1.1pm0.2. All the results are in excellent agreement with predictions of the theory for the graphene-solution interface. This minimally-perturbative method for monitoring charge-transfer at the sub-pC scale exhibits low noise and ultra-low power consumption (~ fW), making it well-suited for use in low-level bioelectronics in liquid environments.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to quantify the basic physical properties of the graphene - solution interface, especially the surface charge density (\(\sigma_s\)) and the interfacial charge - transfer resistance (\(R_{ct}\)). These problems are crucial for graphene biological applications in liquid - phase environments. Specifically: 1. **Surface charge density (\(\sigma_s\))**: Understanding the charge density of adsorbed ions on the graphene surface has an important impact on biochemical processes. Previously, research on the polarity of adsorbed ions was controversial, and there was a lack of accurate measurement methods. 2. **Interfacial charge - transfer resistance (\(R_{ct}\))**: The charge - transfer resistance characterizes the reaction kinetics at the interface and reflects the standard rate constant (\(k_0\)). Traditional methods such as electrochemical impedance spectroscopy (EIS) require the application of an alternating voltage during measurement, which can affect the measurement results. Moreover, these methods are easily affected by factors such as surface contamination and roughness, making it difficult to accurately determine \(R_{ct}\). To solve these problems, the author developed a non - invasive, low - noise charge measurement technique to measure the Faraday charge transfer between the graphene electrode and the aqueous solution by the zero - bias method. This method can accurately measure the charge accumulation and transfer processes at the graphene - solution interface without applying an external voltage, thereby solving the above - mentioned problems and providing more reliable experimental data. Finally, the author measured by this method: - The surface charge density of adsorbed ions is approximately \(- 32.8 \, \text{mC m}^{-2}\) - The specific charge - transfer resistance is \(6.5\pm0.3 \, \text{MΩ cm}^2\) In addition, the \(1/f^\alpha\) characteristic of current noise (\(\alpha = 1.1\pm0.2\)) was also observed in the experiment, which is consistent with theoretical predictions. These results lay the foundation for further development of low - power - consumption, high - sensitivity nano - biosensors.