Model-based Catheter Segmentation in MRI-images

Andre Mastmeyer,Guillaume Pernelle,Lauren Barber,Steve Pieper,Dirk Fortmeier,Sandy Wells,Heinz Handels,Tina Kapur
DOI: https://doi.org/10.48550/arXiv.1705.06712
2020-12-10
Abstract:Accurate and reliable segmentation of catheters in MR-guided interventions remains a challenge, and a step of critical importance in clinical workflows. In this work, under reasonable assumptions, mechanical model based heuristics guide the segmentation process allows correct catheter identification rates greater than 98% (error 2.88 mm), and reduction in outliers to one-fourth compared to the state of the art. Given distal tips, searching towards the proximal ends of the catheters is guided by mechanical models that are estimated on a per-catheter basis. Their bending characteristics are used to constrain the image feature based candidate points. The final catheter trajectories are hybrid sequences of individual points, each derived from model and image features. We evaluate the method on a database of 10 patient MRI scans including 101 manually segmented catheters. The mean errors were 1.40 mm and the median errors were 1.05 mm. The number of outliers deviating more than 2 mm from the gold standard is 7, and the number of outliers deviating more than 3 mm from the gold standard is just 2.
Computer Vision and Pattern Recognition
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to accurately and reliably segment catheters in MRI - guided interventional procedures. Specifically, since catheters in MRI images can produce artifacts that are difficult to interpret, making automatic catheter segmentation very challenging. This problem is particularly important in the clinical workflow because performing this task manually is both time - consuming and error - prone, requiring a high level of operator concentration. Therefore, the paper proposes a heuristic method based on a mechanical model to guide the catheter segmentation process, aiming to improve the accuracy of catheter identification and reduce the number of outliers. The main contributions of the paper include: - Developing a method based on a mechanical model to constrain image feature candidate points by estimating the bending characteristics of each catheter, thereby achieving high - precision catheter segmentation. - Proposing a method of searching from the distal end to the proximal end of the catheter, using the mechanical model to guide the search process. - Verifying the effectiveness of this method on a database containing MRI scans of 10 patients, including 101 manually segmented catheters. The experimental results show that the average error of this method is 1.40 millimeters, the median error is 1.05 millimeters, and compared with the existing technology, the number of outliers is reduced by three - quarters. Through these improvements, the paper makes an important contribution to improving the clinical usability of catheter - based interventional procedures under MRI guidance.