Effect of Myocardial Bridge on the Proximal Inner Diameter Change Rate of Tunneled Artery
Xiao-fei DENG,Pei-jun WANG,Zheng SHU,Chen-jin GE
DOI: https://doi.org/10.3969/j.issn.1006-5741.2017.04.007
2017-01-01
Abstract:Purpose:To assess the effect of myocardial bridge on the inner diameter change rate of proximal tunneled artery by multi-slice computed tomography angiography.Methods:Seventy-nine patients,who were undergone coronary artery computed tomography angiography from Oct 2016 to Jan 2017 in Shanghai TCM-integrated hospital,were enrolled.There were 27 cases that were with myocardial bridge in LAD and 52 cases without myocardial bridge as control group.We reconstructed 45% phase as systole phase and 75% phase as diastole phase in all data.The long and short diameters of cross sections of proximal LAD and RCA were measured by using vitrea 2 workstation.The change rate of coronary artery's inner diameter was calculated by the formula:the change rate of coronary artery's inner diameter =(the diameter of coronary artery in systolic phase -the diameter of coronary artery in diastolic phase) / the diameter of coronary artery in systolic phase *100%,[DCR=100%×(Dsys-Ddia)/Dsys].The difference of DCR between the myocardial bridge group and control group was compared.Results:The DCR of proximal RCA in myocardial bridge group was 13.41% ± 7.85%,in control group was 10.40% ± 9.60%,there was no statistical significant difference between them (t=1.399,P=0.166,P>0.05).The DCR of proximal LAD in myocardial bridge group was 10.85% ± 14.66%,in the control group was 11.81% ±11.51%,there was no statistical significant difference between them (t=-0.318,P=0.751,P>0.05);the DCR of the length diameter of LAD proximal in myocardial bridge group was 7.59% ± 7.05%,and it was 12.75% ± 12.36% in the control group,the DCR of the length diameter of LAD proximal in the control group was significantly higher than that of myocardial bridge group (t=-2.0,P=0.049,P<0.05),but there was no significant difference of the DCR of the short diameter of LAD in the both groups (t=-0.078,P=0.938,P>0.05);there was no statistical significant difference of the DCR of length and short diameters of RCA in both groups (t=0.855,P=0.395,P>0.05 and t=1.42,P=0.16,P>0.05).Conclusion:The length diameter of LAD in myocardial bridge group was smaller than that of the control group.The results showed that myocardial bridge had a significant effect on the DCR of the length diameter of the proximal of tunneled artery.