Label-free single molecule imaging with numerical aperture-shaped interferometric scattering microscopy

Daniel Cole,Gavin Young,Alexander Weigel,P. Kukura
DOI: https://doi.org/10.48550/arXiv.1611.05081
2016-11-16
Abstract:Our ability to optically interrogate nanoscopic objects is controlled by the difference between their extinction cross sections and the diffraction limited area to which light can be confined in the far field. We show that a partially transmissive spatial mask placed near the back focal plane of a high numerical aperture microscope objective enhances the extinction contrast of a scatterer near an interface by approximately $T^{-1/2}$, where T is the transmissivity of the mask. Numerical aperture based differentiation of background from scattered light represents a general approach to increasing extinction contrast and enables routine label free imaging down to the single molecule level.
Optics,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to improve the single - molecule imaging sensitivity of non - fluorescent substances under an optical microscope. Specifically, the authors proposed an interferometric scattering microscopy technique (iSCAT) based on numerical aperture filtering. By placing a partially transmissive spatial mask on the back - focal plane of a high - numerical - aperture microscopic objective, the contrast between the scatterer and the background is enhanced, thereby achieving label - free single - molecule imaging. ### Main problems 1. **Background signal suppression**: When detecting weak scatterers (such as single proteins), the background signal (such as scattering caused by the roughness of the cover glass) in traditional interferometric scattering microscopy (iSCAT) is very strong, resulting in a low signal - to - noise ratio and making it difficult to distinguish the target signal. 2. **High - sensitivity imaging**: How to reduce the background signal while maintaining high sensitivity to make single - molecule imaging possible. ### Solutions 1. **Use of a partial reflector**: By placing a partial reflector on the back - focal plane of the microscope objective, the background signal can be effectively suppressed while the scattering signal is retained. The transmittance \(T\) of the partial reflector can be adjusted to optimize the contrast. 2. **Numerical aperture filtering**: Utilizing the directional differences between scattered light and background light, the scattering contrast is further enhanced through numerical aperture filtering. 3. **Fast - scanning light beam**: Combined with the fast - scanning light beam technology, the imaging quality can be further improved and background interference can be reduced without increasing the experimental complexity. ### Key formulas - **Detected light intensity**: \[ I_{\text{det}} = |E_{\text{inc}}|^2\left[r^2+|s|^2 + 2r|s|\cos\phi\right] \] where \(E_{\text{inc}}\) is the incident electric field, \(r^2\) is the reflectivity of the sample or interface, \(s\) is the scattering amplitude of the object of interest, and \(\phi\) is the phase difference between the scattered field and the transmitted field at the detector. - **iSCAT contrast**: \[ \frac{I_{\text{det}}}{I_{\text{bkg}}} = 1+\frac{2|s|\cos\phi}{r} \] where \(I_{\text{det}}\) is the detected light intensity in the presence of a scatterer, and \(I_{\text{bkg}}\) is the background light intensity in the absence of a scatterer. ### Experimental results - **Enhanced contrast**: After using the partial reflector, the scattering contrast is increased by about 10 times, making the roughness of the cover glass clearly visible in a single shot. - **Real - time imaging**: Through ratio imaging technology, the binding and dissociation events of single molecules can be detected in real time without the need for complex sample drift control. - **High sensitivity**: Combined with the fast - scanning light beam technology, high - signal - to - noise - ratio imaging of 396 kDa proteins can be achieved, with a signal - to - noise ratio of 23. In summary, this paper significantly improves the sensitivity and contrast of interferometric scattering microscopy by introducing partial reflector and numerical aperture filtering technologies, providing a new and effective method for label - free single - molecule imaging.