Continued decay in the cyclotron line energy in Hercules X-1

R. Staubert,D. Klochkov,V. Vybornov,J. Wilms,F.A. Harrison
DOI: https://doi.org/10.1051/0004-6361/201527955
2016-04-19
Abstract:The centroid energy Ecyc of the cyclotron line in the spectrum of the binary X-ray pulsar Her X-1 had been found to decrease with time on a time scale of a few tens of years - surprisingly short astrophysically. This was found for the pulse phase averaged line centroid energy using observational data from various X-ray satellites over the time frame 1996 to 2012, establishing a reduction of about 4 keV. Here we report on the result of a new observation by NuSTAR performed in August 2015. The earlier results are confirmed and strengthened, with respect to both, the dependence of Ecyc on flux (it is still present after 2006) and the dependence on time: the long-term decay continued with the same rate, corresponding to a reduction of about 5 keV in 20 years.
High Energy Astrophysical Phenomena
What problem does this paper attempt to address?
The problem that this paper attempts to solve is about the time - variation of the cyclotron absorption line energy ($E_{\text{cyc}}$) of the X - ray pulsar Her X - 1 in a binary star system. Specifically, the study found that the cyclotron absorption line energy of Her X - 1 has been decreasing at a rate of about 4 keV per year over the past few decades, and this phenomenon appears extremely short on the astrophysical scale. In addition, the paper also explored the relationship between the cyclotron absorption line energy and the X - ray luminosity (or flux), and how this relationship changes over time. ### Main problems 1. **Time evolution of cyclotron absorption line energy**: - The study found that the cyclotron absorption line energy of Her X - 1 has been continuously decreasing at a rate of about 0.26 keV per year over the past 20 years. This long - term attenuation phenomenon was further confirmed by the NuSTAR observation data in 2015. - By analyzing the data of different satellites from 1996 to 2015, the paper used the linear fitting method to determine the attenuation rate of the cyclotron absorption line energy with time. 2. **Relationship between cyclotron absorption line energy and X - ray luminosity**: - Previous studies have found that there is a positive correlation between the cyclotron absorption line energy and the X - ray luminosity, that is, as the X - ray luminosity increases, the cyclotron absorption line energy also increases. - The paper further verified that this relationship still holds after 2006, and through new observation data, it was confirmed that the slope of this dependence has not changed significantly. ### Formulas - Relationship between cyclotron absorption line energy and magnetic field strength: \[ E_{\text{cyc}}=\frac{\hbar e B}{m_e c} = 11.6 \, \text{keV} \times B_{12} \] where $B_{12}=\frac{B}{10^{12} \, \text{G}}$. - Variation of cyclotron absorption line energy with time and luminosity: \[ E_{\text{cyc}}(\text{calc})=E_0 + a\cdot(F - F_0)+b\cdot(T - T_0) \] where $F$ is the X - ray luminosity (in ASM - cts/s), $F_0 = 6.80 \, \text{ASM - cts/s}$; $T$ is the time (in MJD), $T_0 = 53500$. ### Conclusion The paper confirmed the long - term attenuation phenomenon of the cyclotron absorption line energy of Her X - 1 with time through new observation data, and verified the positive correlation between the cyclotron absorption line energy and the X - ray luminosity. These results are of great significance for understanding the physical mechanisms of X - ray pulsars, especially regarding the changes in magnetic field strength and accretion processes.