Analytical tools for single-molecule fluorescence imaging in cellulo

Mark Leake
DOI: https://doi.org/10.48550/arXiv.1504.03486
2015-04-14
Abstract:Recent technological advances in cutting-edge ultrasensitive fluorescence microscopy have allowed single-molecule imaging experiments in living cells across all three domains of life to become commonplace. Single-molecule live-cell data is typically obtained in a low signal-to-noise ratio (SNR) regime sometimes only marginally in excess of 1, in which a combination of detector shot noise, sub-optimal probe photophysics, native cell autofluorescence and intrinsically underlying stochastic of molecules result in highly noisy datasets for which underlying true molecular behaviour is non-trivial to discern. The ability to elucidate real molecular phenomena is essential in relating experimental single-molecule observations to both the biological system under study as well as offering insight into the fine details of the physical and chemical environments of the living cell. To confront this problem of faithful signal extraction and analysis in a noise-dominated regime, the needle in a haystack challenge, such experiments benefit enormously from a suite of objective, automated, high-throughput analysis tools that can home in on the underlying molecular signature and generate meaningful statistics across a large population of individual cells and molecules. Here, I discuss the development and application of several analytical methods applied to real case studies, including objective methods of segmenting cellular images from light microscopy data, tools to robustly localize and track single fluorescently-labelled molecules, algorithms to objectively interpret molecular mobility, analysis protocols to reliably estimate molecular stoichiometry and turnover, and methods to objectively render distributions of molecular parameters
Biomolecules,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to extract the real molecular behaviors from highly noisy datasets when conducting single - molecule fluorescence imaging experiments in living cells. Specifically, the paper focuses on improving the ability to analyze single - molecule behaviors through a series of objective, automated, and high - throughput analysis tools under low signal - to - noise ratio (SNR) conditions, so as to more accurately understand molecular phenomena in biological systems and their physicochemical environments. ### Main Challenges 1. **Low Signal - to - Noise Ratio**: Single - molecule living - cell data are usually obtained under low signal - to - noise ratio conditions, which makes it very difficult to identify the real molecular behaviors. 2. **Noise Sources**: These include shot noise of detectors, poor photophysical properties of probes, autofluorescence of cells themselves, and the intrinsic randomness of molecules. 3. **Dynamic Changes**: The spatial and temporal dependence of the internal environment of cells leads to a high degree of heterogeneity in molecular behaviors. ### Solutions The paper proposes a series of analysis methods aimed at overcoming the above challenges: 1. **Image Segmentation**: - **Automatic Segmentation**: A method based on maximum a posteriori probability (MAP) has been developed to determine cell boundaries, improving the accuracy of cell shape reconstruction. - **Point Spread Function (PSF) Correction**: The point spread function of the imaging system is considered to reduce the impact of cell boundary blurring. 2. **Single - Molecule Localization and Tracking**: - **Background Noise Estimation**: The expectation - maximization (EM) algorithm is used to estimate the mean and variance of background noise. - **Particle Identification**: Laplacian of Gaussian (LoG) filtering and morphological filtering are used to identify and precisely locate single fluorescently - labeled molecules. - **Sub - pixel Precision**: The two - dimensional Gaussian model is utilized to fit the pixel intensity distribution of each particle, achieving sub - pixel - level localization accuracy. 3. **Molecular Dynamics Analysis**: - **Mobility Interpretation**: Algorithms have been developed to objectively interpret molecular mobility, including the estimation of diffusion coefficients. - **Molecular Composition and Turnover**: Analysis protocols have been proposed to reliably estimate molecular composition and turnover rates. 4. **Molecular Parameter Distribution**: - **Statistical Analysis**: Methods have been developed to objectively render the distribution of molecular parameters, thereby generating meaningful statistical data. ### Specific Applications These analysis tools are applied in practical case studies, including: - **Cell Image Segmentation**: Precisely segmenting cell boundaries from microscope images. - **Single - Molecule Localization and Tracking**: Precisely locating and tracking single fluorescently - labeled molecules in living cells. - **Molecular Dynamics Analysis**: Studying the diffusion coefficients of protein complexes and the composition and turnover rates of molecular machines. Through these methods, the paper aims to provide a comprehensive set of tools to help researchers extract real single - molecule behaviors in highly noisy environments, thereby better understanding biochemical and physicochemical processes within living cells.