Surface sensitivity of the spin Seebeck effect

Aisha Aqeel,Ivan J. Vera-Marun,Bart J. van Wees,Thomas T. M. Palstra
DOI: https://doi.org/10.1063/1.4897933
2014-12-22
Abstract:We have investigated the influence of the interface quality on the spin Seebeck effect (SSE) of the bilayer system yttrium iron garnet (YIG) - platinum (Pt). The magnitude and shape of the SSE is strongly influenced by mechanical treatment of the YIG single crystal surface. We observe that the saturation magnetic field H_{sat} for the SSE signal increases from 55.3 mT to 72.8 mT with mechanical treatment. The change in the magnitude of H_{sat} can be attributed to the presence of a perpendicular magnetic anisotropy due to the treatment induced surface strain or shape anisotropy in the Pt/YIG system. Our results show that the SSE is a powerful tool to investigate magnetic anisotropy at the interface.
Materials Science
What problem does this paper attempt to address?