Exploring the preferred load pattern and physiological intensity for on-road exercising with electrically assisted bicycles
Sheng-Chieh Yang,Yun-Ju Lee
DOI: https://doi.org/10.1016/j.jth.2024.101831
IF: 3.613
2024-05-23
Journal of Transport & Health
Abstract:Introduction Electrically-assisted bicycle (e-bike) riding is associated with health and environmental benefits. Through controlling assistive power and transmission settings, e-bike riders could theoretically manage their physical load to a preferred level under environmental resistance. The study aimed to examine whether using e-bikes for transportation can provide health benefits, despite barriers such as control complexity, and to assess if the physical activity associated with e-bike riding meets the recommended health standards. Methods A simulated indoor e-bike riding session with disturbances of environmental resistance was conducted to investigate riders' preferred load, control behaviors, and physiological and subjective responses. During the riding session, participants completed seven consecutive 3-min stages with preset resistance changes. They were directed to maintain their preferred resistance by adjusting the e-bike's assistive level and transmission. Results Twenty-three non-athlete participants completed the simulated e-bike riding session. The preferred load ranged from 0.92 to 1.17 W/kg (watts/body mass). It resulted in a moderate heart rate (66.77% maximal heart rate), metabolic equivalent of task (5.41 MET), and rate of perceived exertion (RPE: 12). The participants kept a stable intensity, regardless of higher or lower power output demand induced by the environmental resistance. Most of the e-bike controls take place right after external resistance changes. In contrast, only a tiny amount occurred at the end of each stage, indicating the urgent intent to retain the preferred intensity. Conclusions The preferred riding load and corresponding intensity were characterized by a stable pattern. An e-bike control strategy with a default assistive mode was suggested to automatically keep the rider's load at 0.92–1.17 W/kg, which might decrease the required manual controls, especially in variegated external resistance situations. Moreover, the moderate physiological responses induced by the self-selected intensity meet the criteria for generating health benefits and support the advocacy of on-road exercising by e-bikes.
public, environmental & occupational health,transportation
What problem does this paper attempt to address?