Oscillating endoskeletal antibubbles

Nobuki Kudo,Rustem Uzbekov,Ryonosuke Matsumoto,Ri-ichiro Shimizu,Craig Carlson,Nicole Anderton,Aurélie Deroubaix,Clement Penny,Albert T. Poortinga,David M. Rubin,Ayache Bouakaz,Michiel Postema
DOI: https://doi.org/10.48550/arXiv.1910.02730
2019-10-07
Soft Condensed Matter
Abstract:An antibubble is a gas bubble with a liquid droplet inside. Antibubbles have a potential role in ultrasonic imaging, ultrasound-guided drug delivery, and hydrocarbon leakage detection. The liquid core droplets inside antibubbles can be stabilised with a process called Pickering stability. Other systems proposed include spoke crystals to suspend the droplet or endoskeletal structures. In this study, the oscillatory response of microscopic endoskeletal antibubbles to ultrasound has been investigated, primarily to determine whether the presence of an endoskeleton attenuates the oscillation amplitude of the antibubble. Three emulsions containing (anti)bubbles were prepared for evaluation. Each emulsion was pipetted into the observation chamber of a high-speed microscopic observation system. A high-speed camera, operating at 10 million frames per second, was couples to the microscope. During camera recording, the materials were subjected to ultrasound pulses from a laboratory-assembled single-element transducer. The presence of an endoskeleton with droplets hampers the oscillation of antibubbles as compared to identical bubbles without endoskeleton and droplet content.
What problem does this paper attempt to address?