Overlap Technique for End-Cap Seals on Cylindrical Magnetic Shields

S. Malkowski,R.Y. Adhikari,J. Boissevain,C. Daurer,B.W. Filippone,B. Hona,B. Plaster,D. Woods,H. Yan
DOI: https://doi.org/10.1109/TMAG.2012.2215047
2013-07-03
Abstract:We present results from studies of the effectiveness of an overlap technique for forming a magnetic seal across a gap at the boundary between a cylindrical magnetic shield and an end-cap. In this technique a thin foil of magnetic material overlaps the two surfaces, thereby spanning the gap across the cylinder and the end-cap, with the magnetic seal then formed by clamping the thin magnetic foil to the surfaces of the cylindrical shield and the end-cap on both sides of the gap. In studies with a prototype 31-cm diameter, 91-cm long, 0.16-cm thick cylindrical magnetic shield and flared end-cap, the magnetic shielding performance of our overlap technique is comparable to that obtained with the conventional method in which the end-cap is placed in direct lapped contact with the cylindrical shield via through bolts or screws.
Instrumentation and Detectors
What problem does this paper attempt to address?