A Carbon Nanotube Immunosensor for Salmonella

Mitchell Lerner,Brett Goldsmith,Ronald McMillon,Jennifer Dailey,Shreekumar Pillai,Shree R. Singh,A.T. Charlie Johnson
DOI: https://doi.org/10.1063/1.3658573
2013-02-13
Abstract:Antibody-functionalized carbon nanotube devices have been suggested for use as bacterial detectors for monitoring of food purity in transit from the farm to the kitchen. Here we report progress towards that goal by demonstrating specific detection of Salmonella in complex nutrient broth solutions using nanotube transistors functionalized with covalently-bound anti-Salmonella antibodies. The small size of the active device region makes them compatible with integration in large-scale arrays. We find that the on-state current of the transistor is sensitive specifically to the Salmonella concentration and saturates at low concentration (<1000 cfu/ml). In contrast, the carrier mobility is affected comparably by Salmonella and other bacteria types, with no sign of saturation even at much larger concentrations (10^8 cfu/ml).
Materials Science
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a fast, sensitive and highly specific sensor for detecting Salmonella in food. Specifically, the research aims to achieve efficient detection of Salmonella by constructing an immunosensor based on carbon nanotubes (CNT). The following are the specific background and requirements of this problem: 1. **Food safety issues**: - In the United States each year, microbial pathogens cause approximately 6.5 million to 81 million cases of food - borne diseases, resulting in significant mortality and economic losses, estimated to cost between $2.9 billion and $6.7 billion annually. - Salmonella is a major cause of food - borne diseases in the United States and is present in fresh produce as well as in animal hosts such as chicken, pork and seafood. 2. **Limitations of existing detection methods**: - **Traditional bacterial culture methods**: It takes at least 72 hours to confirm a positive result. - **PCR - based methods**: Although very sensitive, they require pure samples, a long processing time and expertise in molecular biology. - **ELISA or PCR detection**: Although faster, they may also require pure samples, a long processing time, expertise and are relatively costly. 3. **Ideal sensor characteristics**: - Miniaturized and inexpensive, able to automate the detection of food - borne diseases at all stages of the food chain (from harvest, transportation to the point of use in the kitchen). - Combining biorecognition elements and all - electronic nano - readout elements, able to simultaneously quantify hundreds of biological or biomolecular targets in a single small - volume sample. 4. **Advantages of CNT - based immunosensors**: - Carbon nanotube field - effect transistors (CNT FETs) have a well - developed electronic technology, extremely high inherent sensitivity and good carbon surface chemistry properties, allowing for flexible functionalization strategies. - By covalently binding anti - Salmonella antibodies to the sidewalls of carbon nanotubes, the conformation and position of biorecognition elements can be better controlled, thereby improving the specificity and performance of the sensor. Therefore, the focus of this research is to develop a small - area (2.5 μm × 15 μm channel area) immunosensor based on carbon nanotubes for detecting Salmonella in nutrient broth. The experimental results show that this sensor can significantly reduce the ON - state current at a concentration as low as 1000 colony - forming units (cfu)/ml, and this change is specific to Salmonella. In addition, the change in carrier mobility is also related to the bacterial concentration, which provides more possibilities for further applications. ### Formula Explanation - The formula for calculating carrier mobility \(\mu\) is: \[ \mu=\frac{L}{C_g}\cdot\left(\frac{\partial I_{\text{max}}}{\partial V_g}\right) \] where: - \(L\) is the channel length (2 μm) - \(C_g\) is the back - gate capacitance (340 fF/cm²) - \(\frac{\partial I_{\text{max}}}{\partial V_g}\) is the maximum slope of the I - Vg curve These research results indicate that CNT - based immunosensors have great potential in practical applications, especially for the rapid detection of Salmonella in complex real - world samples.