Premature failure of a hip hemiarthroplasty secondary to osteolysis and aseptic loosening

Marco Rizzo,Thomas B Pace
Abstract:Bipolar hemiarthroplasty and unipolar hemiarthroplasty have been widely used, especially in cases of femoral neck fracture in elderly patients. In this article, we report on a single case of premature loosening of a bipolar endoprosthesis secondary to presence of titanium and polyethylene debris from wear. We removed the patient's prosthesis and performed a total hip arthroplasty. With use of improved surgical and cementing techniques, state-of-the-art biomaterials, and better patient selection, hemiarthroplasties recently became as long-lived a stotal hip arthroplasties. However, our patient's case of premature loosening points up some basic principles regarding the tribology of implant failure: First, the surface of titanium is poor for articulation; second, polyethylene wear, especially in cases of bipolar hemiarthroplasty with a thin liner and in the presence of titanium prostheses, may hasten failure; third, meticulous third-generation cementing techniques minimize the risk for premature failure; and fourth, hemiarthroplasties performed in patients with previous surgery have higher rates of premature failure.
What problem does this paper attempt to address?