A validation methodology aid for improving a thermal building model: Case of diffuse radiation accounting in a tropical climate

A. J. P. Lauret,T. A. Mara,H. Boyer,L. Adelard,F. Garde
DOI: https://doi.org/10.48550/arXiv.1212.3928
2012-12-17
Abstract:As part of our efforts to complete the software CODYRUN validation, we chose as test building a block of flats constructed in Reunion Island, which has a humid tropical climate. The sensitivity analysis allowed us to study the effects of both diffuse and direct solar radiation on our model of this building. With regard to the choice and location of sensors, this stage of the study also led us to measure the solar radiation falling on the windows. The comparison of measured and predicted radiation clearly showed that our predictions over-estimated the incoming solar radiation, and we were able to trace the problem to the algorithm which calculates diffuse solar radiation. By calculating view factors between the windows and the associated shading devices, changes to the original program allowed us to improve the predictions, and so this article shows the importance of sensitivity analysis in this area of research.
Computational Engineering, Finance, and Science
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the inaccurate prediction of solar radiation entering the room through windows by the building thermal model under tropical climate conditions. Specifically, the research has found that the existing models over - estimate the direct and diffuse solar radiation entering the room through windows, especially when dealing with diffuse radiation. This over - estimation has led to errors in indoor temperature prediction. Therefore, the main objective of the paper is to improve the model so that it can more accurately predict the solar radiation entering the room through windows with shading devices, especially the influence of diffuse radiation. To achieve this goal, the author adopted the following methods: 1. **Sensitivity analysis**: Through sensitivity analysis, the key parameters affecting indoor temperature prediction were determined, especially direct and diffuse solar radiation. 2. **Experimental design**: Sensors were installed on the selected building to measure the outdoor and indoor solar radiation for comparison with the model predictions. 3. **Model improvement**: The concept of view factors was introduced to calculate the interaction between the window and the shading device, thereby improving the model's prediction of diffuse radiation. 4. **Time - frequency analysis**: Time - frequency analysis techniques were used to identify the sources of model prediction errors, especially the influence of diffuse radiation. Through these methods, the author has successfully improved the prediction accuracy of the model for solar radiation entering the room through windows, especially in cases where diffuse radiation is dominant. This not only improves the prediction of indoor temperature but also provides more reliable data support for building design under tropical climate conditions.