The design of the Ali CMB Polarization Telescope receiver
Maria Salatino,Jason E. Austermann,Keith L. Thompson,Peter A. R. Ade,Xiran Bai,James A. Beall,Dan T. Becker,Yifu Cai,Zhi Chang,Ding Chen,Pisin Chen,Jake Connors,Jacques Delabrouille,Bradley Dober,Shannon M. Duff,Guanhua Gao,Shamik Ghosh,Richard C. Givhan,Gene C. Hilton,Bin Hu,Johannes Hubmayr,Ethan D. Karpel,Chao-Lin Kuo,Hong Li,Mingzhe Li,Si-Yu Li,Xufang Li,Yongping Li,Michael Link,Hao Liu,Liyong Liu,Yang Liu,Fangjun Lu,Xuefeng Lu,Tammy Lukas,John A. B. Mates,Justin Mathewson,Philip Mauskopf,Jeremy Meinke,Jordi A. Montana-Lopez,Jenna Moore,Jingyan Shi,Adrian K. Sinclair,Ryan Stephenson,Weishin Sun,Yu-Han Tseng,Carole Tucker,Joel N. Ullom,Leila R. Vale,Jeff van Lanen,Michael R. Vissers,Samantha Walker,Bo Wang,Guofeng Wang,Jiaxin Wang,Erik Weeks,Di Wu,Yi-Han Wu,Junqing Xia,He Xu,Ji Yao,Yongqiang Yao,Ki Won Yoon,Bin Yue,Hua Zhai,Aimei Zhang,Laiyu Zhang,Le Zhang,Pengjie Zhang,Tong Zhang,Xinmin Zhang,Yifei Zhang,Yongjie Zhang,Gong-Bo Zhao,Wen Zhao
DOI: https://doi.org/10.1117/12.2560709
2021-01-01
Abstract: Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4{\deg} field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.