Gas Sensor Detecting 3-Hydroxy-2-butanone Biomarkers: Boosted Response via Decorating Pd Nanoparticles onto the {010} Facets of BiVO 4 Decahedrons

Jian Chen,Dongliang Feng,Chen Wang,Xiaxia Xing,Lingling Du,Zhengyou Zhu,Xiaohu Huang,Dachi Yang
DOI: https://doi.org/10.1021/acssensors.0c01149
IF: 8.9
2020-08-06
ACS Sensors
Abstract:The newly emerged gas sensing detection of 3-hydroxy-2-butanone (3H-2B) biomarker is deemed as an effective avenue to indirectly monitor <i>Listeria monocytogenes</i> (LM). However, 3H-2B sensing materials requiring critically high sensitivity and selectivity, and ppb-level detection limit, remain challenging. Here, we report the advanced gas sensors built with bismuth vanadate microdecahedron (BiVO<sub>4</sub> MDCD) {010} facets selectively decorated with Pd nanoparticles (Pd NPs, Pd-{010}BiVO<sub>4</sub> MDCDs) for boosted detection of the 3H-2B biomarker. Meanwhile, BiVO<sub>4</sub> MDCDs with overall facets are randomly deposited with Pd NPs (Pd-BiVO<sub>4</sub> MDCDs). Comparatively, Pd-{010}BiVO<sub>4</sub> MDCD sensors show 1 order of magnitude higher response toward the 3H-2B biomarker at 200 °C. Further, Pd-{010}BiVO<sub>4</sub> MDCD sensors enable to detect as low as 0.2 ppm 3H-2B and show best selectivity and stability, and fastest response and recovery. Density functional theory calculations reveal a lower adsorption energy of 3H-2B onto Pd-{010}BiVO<sub>4</sub> MDCDs than those of pristine and Pd-BiVO<sub>4</sub> MDCDs. The extraordinary Pd-{010}BiVO<sub>4</sub> sensing performance is ascribed to the Pd NP-assisted synergetic effect of the preferential adsorption of 3H-2B target molecules, accumulated sensing agent of ionic oxygen species, and concentrated catalysts on the {010} facets. This strategy offers rapid and noninvasive detection of LMs and is thus of great potential in the upcoming Internet of Things.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acssensors.0c01149?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acssensors.0c01149</a>.Detailed fabrication process; schematic diagram of synthetic arts; SEM image and EDS elemental mappings of Pd-BiVO<sub>4</sub> and Pd-{010}BiVO<sub>4</sub>; XRD patterns corresponding to pristine BiVO<sub>4</sub>, Pd-BiVO<sub>4</sub>, and Pd-{010}BiVO<sub>4</sub> before and after annealing; selectivity of pristine BiVO<sub>4</sub>, Pd-BiVO<sub>4</sub>, and Pd-{010}BiVO<sub>4</sub> toward 10 ppm 3H-2B; response time and recovery time of pristine BiVO<sub>4</sub>, Pd-BiVO<sub>4</sub>, and Pd-{010}BiVO<sub>4</sub> toward 10 ppm 3H-2B at 200 °C; resistance variations of pristine BiVO<sub>4</sub>, Pd-{010}BiVO<sub>4</sub>, and Pd-BiVO<sub>4</sub> toward 10 ppm 3H-2B at 200 °C; long-term stability of a rebuilted Pd-{010}BiVO<sub>4</sub> MDCDs sensor; XPS spectra of Bi and V for pristine BiVO<sub>4</sub>, Pd-BiVO<sub>4</sub>, and Pd-{010}BiVO<sub>4</sub>; and XPS spectra of Pd 3d for Pd-BiVO<sub>4</sub> and Pd-{010}BiVO<sub>4</sub> after annealing (<a class="ext-link" href="/doi/suppl/10.1021/acssensors.0c01149/suppl_file/se0c01149_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology
What problem does this paper attempt to address?