Radiometric Cross-Calibration of GF-4/IRS Based on MODIS Measurements

Xiang Zhou,Duo Feng,Yong Xie,Zui Tao,Tingting Lv,Jin Wang
DOI: https://doi.org/10.1109/jstars.2021.3091977
IF: 4.715
2021-01-01
IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Abstract:GaoFen-4 (GF-4) infrared spectrum (IRS) camera has a special spectral band located in the mid-wave infrared spectrum with the wavelength ranging from 3.50 to 4.10 μm. It is very important for forest fire-detection and other quantitative remote sensing applications at a high spatial resolution of 400 m. Due to the similarity of the spectral characteristics, the thermal emissive band 20 (3.660–3.840 μm) and 22 (3.929–3.989 μm) of medium resolution imaging spectrometer (MODIS) are taken as the reference bands for the radiometric cross-calibration of the GF-4/IRS camera. The time difference between selected GF-4/IRS and MODIS images at the Qinghai Lake and Se lincuo Lake test sites is less than one hour. After spatial matching, single-band and dual-band spectral matching methods are proposed in this article. Then, the DN value of GF-4 image is linearly fitted to the radiance of the corresponding MODIS image to obtain the radiometric calibration coefficients of GF-4/IRS camera. The validation results show that the cross-calibration coefficients calculated by integrating the measurement of two MODIS bands with the mean value spectral matching approach has the highest radiometric calibration consistency with the official calibration coefficients.
imaging science & photographic technology,remote sensing,engineering, electrical & electronic,geography, physical
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve This paper aims to address the on-orbit radiometric calibration issue of the infrared spectrum (IRS) camera on the GF-4 satellite. Specifically, the research objectives are as follows: 1. **Increase the Frequency of Radiometric Calibration**: - Currently, due to the lack of an onboard calibrator, the PMS and IRS cameras of the GF-4 satellite can only undergo radiometric calibration once a year using ground station calibration methods. This method is time-consuming and susceptible to weather conditions, making it difficult to eliminate random errors and track the radiometric stability of the sensors. - By using cross-calibration methods, it is possible to obtain radiometric calibration coefficients at a higher frequency, thereby better tracking the radiometric consistency of GF-4/IRS throughout the mission period. 2. **Utilize MODIS as a Reference Sensor**: - Select the multispectral sensor MODIS, which has high radiometric calibration accuracy, as the reference sensor for cross-calibration of GF-4/IRS. - MODIS has excellent radiometric calibration accuracy and can update calibration coefficients every 2 months, ensuring the quality and stability of remote sensing measurements. 3. **Propose Five Spectral Matching Methods**: - Propose single-band and dual-band methods, considering the spectral differences between the two sensors. - The dual-band methods include the average value method, intersection value method, and central wavelength distance method to improve the accuracy of radiometric calibration. 4. **Verify Consistency with Official Calibration Coefficients**: - Use the official calibration coefficients published by the China Resources Satellite Data Center as a reference to verify the accuracy of the cross-calibration results. - The results show that the calibration coefficients obtained using the average value method among the dual-band methods have the highest radiometric calibration consistency. Through these methods, the paper aims to improve the radiometric calibration accuracy and stability of GF-4/IRS and provide reliable data support for subsequent quantitative remote sensing applications.