Evaluation of the Rheological Properties, Preclinical Safety, and Clinical Effectiveness of a New Dispersive Ophthalmic Viscoelastic Device for Cataract Surgery
Claudia Palacio-Pastrana,Patricia Muñoz-Villegas,Fernando Dániel-Dorantes,Alejandra Sánchez-Ríos,Oscar Olvera-Montaño,Yareni I Martínez-Montoya,Juan D Quintana-Hau,Leopoldo M Baiza-Durán
DOI: https://doi.org/10.2147/MDER.S379050
2022-08-25
Medical Devices: Evidence and Research
Abstract:Claudia Palacio-Pastrana, 1 Patricia Muñoz-Villegas, 2 Fernando Dániel-Dorantes, 3 Alejandra Sánchez-Ríos, 2 Oscar Olvera-Montaño, 2 Yareni I Martínez-Montoya, 1 Juan D Quintana-Hau, 3 Leopoldo M Baiza-Durán 2 1 SalaUno Salud, SAPI de CV, México City, México; 2 Regional Medical Affairs Department, Laboratorios Sophia SA de CV, Zapopan, Jalisco, México; 3 Research and Development Department (CIS), Zapopan, Jalisco, México Correspondence: Patricia Muñoz-Villegas, Laboratorios Sophia, SA de CV, Paseo del Norte 5255, Guadalajara Technology Park, Zapopan, Jalisco, 45010, México, Tel +52 3301 4200, Ext: 1018, Email Purpose: To evaluate the rheological properties of the ophthalmic viscoelastic device (OVD) PRO-149, its preclinical safety, and its effectiveness when used during cataract surgery in patients with age-related cataract. Material and Methods: Control (HEC) and test (PRO-149) OVDs were compared through rheological measures, by two preclinical safety studies in rabbits, and under normal-use conditions during cataract removal and lens implantation in a parallel randomized clinical trial. Results: Rheological properties were determined. Preclinical studies did not find any evidence of safety issues or toxicity. In the clinical trial, 36 subjects were included. After 29 days, there were no statistically significant differences in mean percentage of endothelial cell count change or in the postoperative intraocular pressure between groups. There were no significant differences between OVDs for any safety parameter studied. Finally, PRO-149 showed a statistically significant improvement in surgeon rating for ease of use during extraction (p < 0.05). Conclusion: PRO-149 is a dispersive OVD. The rabbit models did not find evidence of clinical alterations or toxicity. The results of the clinical study support that the two studied OVDs were clinically similar in terms of safety and effectiveness for cataract surgery. Trial Registration: The trial is registered at Clinical Trials.gov at NCT04702802 (21– 01-11). Keywords: rheology, sodium hyaluronate, surgical procedure, viscoadaptative, viscosity Ophthalmic viscoelastic devices (OVDs) have been used in eye surgery for more than 50 years, initially as vitreous humor substitutes and later as a tool during cataract surgery. 1,2 The study of the rheological properties of OVDs used during cataract surgery provides important information, allowing the ophthalmic surgeon to better understand and select the ideal OVD among the multiple currently available options. 3 OVDs used in ophthalmic surgery can be classified as viscoadaptative, higher-viscosity cohesive, viscous-cohesive, viscous-dispersive, medium viscosity cohesive, viscous-cohesive, or lower viscosity-dispersive. 3,4 The physical properties that are generally recognized as differentiators among OVDs are their viscosity, elasticity, stiffness, pseudoplasticity and cohesion. These characteristics are translated into tissue protection, space maintenance, and injection and aspiration ease. 1 Viscosity is a parameter used on fluids. In pure substances, it varies significantly depending on the temperature and the pressure applied to them. The ease at which liquids flow is a way to evaluate their viscosity. 5 The dynamic viscosity is the property of fluids characterized for their resistance to flow, due to the friction between their molecules. For some fluids, viscosity is constant, and it depends only on temperature and pressure. These can be grouped as Newtonian fluids. Fluids that do not follow this proportional ratio are denominated non-Newtonian. One of the properties of Newtonian fluids is how their viscosity depends on the shear-rate, property that can be evaluated and measured using the Carreau fluid model. 6,7 The term plasticity refers to a material's capacity to deform continuously, without breaking, when a sufficient force is applied and maintaining a new shape once the force has been interrupted. The more plasticity a material shows the force required to deform it decreases as the deformation velocity increases. 1,5,8 The ability to become less viscous when the shear rate increases when there is a viscosity limited to zero shear is called pseudoplasticity. In this sense, an OVD with high viscosity at zero shear would be ideal to maintain formed spaces; however, pseudoplasticity would allow it to, when injected through a cannula (high shear rate), exhibit a decrease in viscosity, facilitating its application. 1,5 Elasticity is defined as the tendency of a substance to recover its original shape after being deforme -Abstract Truncated-
English Else