Best Practices to Directly Assess Heterogeneous Singlet Oxygen Photosensitization by Phosphorescence
Adrien Schlachter,Paul Asselin,Axel Chatelain,Pierre D. Harvey
DOI: https://doi.org/10.1002/adfm.202404111
IF: 19
2024-05-26
Advanced Functional Materials
Abstract:A method to qualitatively detect singlet oxygen phosphorescence at the solid‐gas interface is presented. It consists mainly of monitoring luminescence intensity in air, then pure oxygen, then pure argon while irradiating the photosensitizer. A direct proof of singlet oxygen photosensitization can therefore be obtained using a low‐power light source and an unmodified fluorimeter. Literature proves that the direct detection of 1O2(1Δg) at the solid gas interface is systematically performed from its phosphorescence using high intensity excitation sources (i.e., lasers), which lead to quasi‐ubiquitous chemical problems, such as sensitizer degradation, and photophysical counter‐active issues such as ultrafast exciton migration, singlet‐singlet and triplet‐triplet annihilation, and thermally activated delayed fluorescence mediated by 1O2(1Δg). To avoid these inconveniences, low excitation intensity is required but leads to serious analytical challenges. The best practices to reliably detect 1O2(1Δg) phosphorescence at various interfaces using a standard excitation source and near‐IR detector. The two main practices consist in a gas purging test for reliable identification of 1O2(1Δg), and in a particularly fine optimization of the angle made by excitation beam versus substrate plane. These practices are applied to porphyrin sensitizers H2TPP and ZnTPP, either neat or physiosorbed on glass, quartz, paper and hospital bandages, graphene oxide (GO), and embedded inside electrospun polystyrene fibers and spin coated poly(methyl methacrylate) films. Porphyrin‐based metal‐organic framework PCN‐224, freshly activated, is also examined.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,nanoscience & nanotechnology