Efficacy of smart device heart rhythm monitoring to detect spontaneous conversion to sinus rhythm in patients scheduled for electric cardioversion of atrial fibrillation. Kardiover Study

J Benezet Mazuecos,P Alonso,J M Lozano,J Salas,O Gonzalez,M Rodriguez-Manero,I Narvaez,I Barrio,J A Iglesias
DOI: https://doi.org/10.1093/europace/euae102.680
2024-05-01
Abstract:Abstract Introduction the management of patients with recent-onset atrial fibrillation (AF) is to achieve sinus rhythm (SR) by electrical or pharmacological cardioversion (CV). However, frequently SR is spontaneously restored, making scheduled admission and/or transesophageal echocardiogram (TEE) unnecessary and therefore causing misutilization of healthcare resources. Emerging medical technology has allowed for monitoring of heart rhythm abnormalities. Objective A prospective multicenter study was designed to evaluate the diagnostic ability of a smart device ECG monitor to detect spontaneous conversion to SR in AF patients, preventing unnecessary admission and providing an earlier management. Methods A prospective multicenter study was designed including patients with first diagnosed, paroxysmal or persistent AF scheduled for ambulatory electrical cardioversion in cardiology departments of 7 hospitals of Spain. Patients were asked to submit ECG recordings to a central Corelab daily, twice a day and whenever they present symptoms, until cardioversion (spontaneous or scheduled) and a week afterwards. Whenever a spontaneous conversion to SR was detected, investigators were contacted to confirm SR and abort admission, likewise when AF recurrence after cardioversion was detected. Patients’ satisfaction was evaluated using a test for perceived utility and value, convenience, and accessibility. Results A total of 62 patients were enrolled (age 62±10 years). Baseline characteristics of the study population are described in the Table. Fifteen patients (24%) did not undergo CV as they showed spontaneous conversion to SR. Among 47 patients admitted for CV, it was successful in 41 (87%). One patient aborted CV because of atrial thrombus on TEE. During follow up after conversion to SR (spontaneous or electrical), recurrences of AF occurred in 20 of 56 patients (36%) correctly detected by the devices. At the end of the follow-up 41 of 56 patients (73%) remained in SR. Due to the early detection of spontaneous conversion to SR, a total of 15 admissions and 9 TEE were prevented and these resources used for other patients. Adherence was high with a rate of ECG transmission over 80% in 56 patients (90%). Perceived satisfaction was also high with an overall punctuation of 9 over 10 in the patient’s feedback test. Conclusion Digital devices for heart rhythm monitoring can optimize the management of AF patients scheduled for CV, avoiding unnecessary admissions and providing a more rational use of healthcare resources.Table
What problem does this paper attempt to address?