Strategic expediency of using an innovative product in the restoration of the energy sector: the experience of Turkey
,Cemal Okuyan,Nataliia Chupryna,,Olena Chernysheva,
DOI: https://doi.org/10.32434/2415-3974-2024-19-1-163-176
2024-01-01
Economic Herald of SHEI USUCT
Abstract:Nowadays, Ukraine is experiencing a full-scale military invasion by Russia, which is causing a large number of casualties among all segments of the population. Many Ukrainian cities have suffered quite heavy damage to their infrastructure. According to Bloomberg, companies from Austria, Germany and Turkey are already operating in Ukraine. An expanding number of foreign companies are increasing their presence in Ukraine, relying on Ukraine’s post-war investment and innovation potential. Ukraine’s post-war development will take into account the latest energy-efficient, environmental, social and economic trends in engineering and technology in various sectors. Considering the climatic conditions in Ukraine, one of the priority areas of reconstruction is to restore heat in buildings (both residential and non-residential) in winter and air conditioning in summer. According to the International Energy Agency for Heating, the use of heat pumps in various industries will continue to grow and should reach at least 75%. Such growth rates in the use of heat pumps are due to a significant reduction in heating or air conditioning costs, environmental safety, and their versatility in use. In this regard, the use of heat pumps in the reconstruction and restoration of Ukrainian residential and non-residential buildings has its advantages and is recommended by many scientists for use. In this study, an application of heat pump originating from aqua-air in Isısan showroom existing in Antalya and some experiments with R514 type heat pump devices existing in air conditioning-cooling lab in Akdeniz University Technical Sciences Vocational High School have been carried out. In both devices in variable conditions water discharge entering into condenser on R514 type testing machine has been considered as 10-50 gr/h variable and accordingly it is observed that the real heating factor of action differ 2,25-7,4 values. On the other hand, the heating factor of action in theoretical state have been calculated and the correlation between them have been examined. Besides this, in LHK-10 type heat pump originating from aqua-air in Antalya Isısan Showroom and the application is completed, temperature rating entering into condenser has been changed between 16 and 32 °C and the heating and cooling factor of action(for both theoretical and real occasions) affecting the heat pump have been calculated. The experimental and the practical results getting from two different places have been analyzed respectively.