Ultrasonic Surgical Aspirator Based Histopathological Assessment in Neuro-Oncology: A Prospective Study at a Tertiary Care Hospital - Elevating Diagnostic Precision in Brain Tumor Specimens

DOI: https://doi.org/10.37184/lnjcc.2789-0112.5.12
2024-01-01
Liaquat National Journal of Cancer Care
Abstract:Background: Ultrasonic surgical aspirators, powered by high-frequency sound waves, represent a cutting-edge tool in neurosurgery. The ongoing study endeavors to thoroughly assess the practicality and effectiveness of employing ultrasonic aspirators in the treatment of central nervous system tumors. Objective: To assess the outcome of the Ultrasonic surgical aspirators in brain surgery tumors can be removed safely without harmful effects on brain parenchyma or the neurovascular structures. Methods: It was a prospective study, we in our study had 64 patients in total that were part of the study; admitted between May 2019 and September 2023 with brain lesions, Department of Neurosurgery, Liaquat University of Medical and Health Sciences, Jamshoro among them males were 38 (59.3%) and females were 26 (40.6%), aged between 16 and 61 (mean 51.6±14.2). 32 patients were treated with Ultrasonic Surgical Aspirator, while in 32 patients the conventional method was adopted, and of them, it was not used. Patients undergoing Ultrasonic Surgical Aspirator had an age range of 16 to 57 years, with a mean age of 48.7±16.6 years. Meanwhile, those who did not undergo Ultrasonic Surgical Aspirator ranged from 30 to 61 years old, with a mean age of 51.1±10.4 years. Results: No significant differences were observed between the two groups in terms of the variable used (p=0.087, p=0.6539 respectively). When comparing operative times, the group utilizing CUSA had an average surgery duration of 210 minutes (ranging from 90 to 260 minutes), while the group not using the ultrasonic aspirator had an average surgery duration of 160 minutes (ranging from 110 to 170 minutes). The mean time of surgery was marked longer in the Ultrasonic Surgical Aspirator was used (p=0.014). Apart that structural changes were found which can alter the grade of the tumor compared to the conventional biopsy. Conclusion: Ultrasonic Surgical Aspirator serves as a valuable alternative in high-risk biopsy scenarios, it's vital to recognize its inherent limitations. With advancements such as digital histopathology and molecular analysis, ensuring the availability of the entire operative specimen for analysis becomes imperative due to the rapid processing capabilities associated with these methodologies.
What problem does this paper attempt to address?