Optimization of a constructed wetland-microbial fuel cell system for Cr(VI) removal from wastewater and power generation performance

Yucui Shi,Yongwei Li,Qing Liu,Shaohong You
DOI: https://doi.org/10.37190/epe240203
2024-01-01
Environment Protection Engineering
Abstract:A new type of bioelectrochemical system features a constructed wetland (CW) coupled with a microbial fuel cell (MFC) to treat Cr(VI) wastewater while generating electricity. The optimal operating parameters for treating wastewater containing Cr(VI) are discussed. The results show that the CW-MFC system is more effective in the treatment of Cr(VI)-containing wastewater and generating electricity. A COD concentration of 300 mg/dm 3 corresponded to the greatest COD and Cr(VI) removal rates with a maximum power density of 505.62 mW/m 3 , whereas a Cr(VI) concentration of 80 mg/dm 3 yielded the greatest COD removal rate, with a maximum power density of 484.43 mW/m 3 . A hydraulic retention time (HRT) of 3 days yielded the largest pollutant removal rates with a maximum power density of 479.21 mW/m 3 . Considering that the comprehensive operating conditions of CW-MFC are based on planting plants, the COD concentration is 300 mg/dm 3 , the Cr(VI) concentration is 80 mg/dm 3 , and the HRT is 3 days. The abundance of electrogenic bacteria Geobacter and metal dissimilatory reducing bacteria Acinetobacter in CW-MFC is higher than that in the control group. The results of this study provide theoretical guidance for determining the optimal operating conditions and energy recovery of the CW-MFC system for treating chromium wastewater.
engineering, environmental
What problem does this paper attempt to address?