LabVIEW-based rotary balance data synchronization acquisition system design

Jian Li,Bingyu Sun
DOI: https://doi.org/10.1088/1742-6596/2787/1/012013
2024-06-01
Journal of Physics: Conference Series
Abstract:Abstract To solve the problem that many high-precision rotating balance bridge output signals and angular phase signals need to be measured synchronously in wind tunnel force measurement experiments, a rotating balance data synchronization acquisition system is designed based on LabVIEW and NI PXIe acquisition board. LabVIEW graphical programming is applied, combined with STM32F407VET6 processor embedded development of the timing divider, using the equal interval method to obtain the required synchronization trigger signals and use them as the digital trigger signals of the NI PXIe acquisition card. In addition, multi-threaded programming technology is used to develop the upper computer software to realize the storage, display, and analysis of the collected data. The test proved that the system has high testing accuracy, a short development cycle, embedded visualization development is easy to debug, stable operation, and real-time and reliable data synchronization acquisition.
What problem does this paper attempt to address?