AI based PD-L1 CPS quantifier software to identify more patients for checkpoint therapy in gastric cancer at pathologist-level interobserver concordance.

Sunil S Badve,George Louis Kumar,Tobias Lang,David Mulder,Diego Calvopiña,Patrick Frey,Maria Karasarides
DOI: https://doi.org/10.1200/jco.2024.42.16_suppl.2633
IF: 45.3
2024-06-01
Journal of Clinical Oncology
Abstract:2633 Background: To determine whether gastric cancer (GC) patients are eligible for immunotherapy, PD-L1 expression is analyzed by immunohistochemistry (IHC) using the “Combined Positive Score” (CPS). This requires quantification of PD-L1 stained tumor and tumor-associated immune cells as well as all viable tumor cells. However, manual CPS scoring on whole-slide images (WSIs) is time-consuming and prone to error as evidenced by low interobserver concordance. While the use of artificial intelligence (AI) holds the promise to ameliorate this key challenge in clinical practice, AI models have not yet met the required accuracy thresholds for PD-L1 CPS scoring on GC biopsies. Methods: We investigated the use of an AI-based PD-L1 CPS quantifier software to support pathologists in standardized PD-L1 IHC assessment on GC biopsies.An AI software for automated PD-L1 CPS scoring was deployed on WSIs from GC biopsies (n = 97) stained for PD-L1 with the 28-8 pharmDx assay and scanned on a 3DHistech P1000 scanner. Manual CPS scores from 12 pathologists on all 97 slides were available for comparison. Pairwise correlation was calculated for continuous values using Lin’s concordance correlation coefficient (CCC). Pairwise concordance was measured for scores binarized at the clinically relevant positivity cutoff of CPS ≥ 5 using unweighted Cohen’s kappa. Results: For continuous CPS scores, the CCC between AI scores and pathologists’ scores was higher (0.59) than the mean correlation among pathologists (0.56). In the majority of cases, the AI scores were found to be within the range of all pathologists, but slightly above the pathologist median. At a cutoff of CPS≥5, the concordance between AI scores and pathologists’ manual scores (κ=0.45) was higher than the mean concordance among pathologists’ manual scores (κ=0.39) (p 50% more) categorized as positive by the AI model. Conclusions: An AI model for the assessment of PD-L1 expression in GC using CPS was applied successfully without human intervention. The correlation in continuous CPS scores as well as the concordance in clinical categories with all pathologists was higher for the AI model than for individual pathologists on average, while at the same time, the AI model found more positive patients. This shows that by using AI more positive patients eligible for PD-L1 targeted treatment might be identified while simultaneously ensuring a level of concordance that is non-inferior to pathologists.
oncology
What problem does this paper attempt to address?