Ionization signals from electrons and alpha-particles in mixtures of liquid Argon and Nitrogen - perspectives on protons for Gamma Resonant Nuclear Absorption applications

M. Zeller,I. Badhrees,S. Delaquis,A. Ereditato,S. Janos,I. Kreslo,M. Messina,U. Moser,B. Rossi
DOI: https://doi.org/10.1088/1748-0221/5/10/P10009
2010-08-24
Abstract:In this paper we report on a detailed study of ionization signals produced by Compton electrons and alpha-particles in a Time Projection Chamber (TPC) flled with different mixtures of liquid Argon and Nitrogen. The measurements were carried out with Nitrogen concentrations up to 15% and a drift electric feld in the range 0-50 kV/cm. A prediction for proton ionization signals is made by means of interpolation. This study has been conducted in view of the possible use of liquid Ar-N2 TPCs for the detection of gamma-rays in the resonant band of the Nitrogen absorption spectrum, a promising technology for security and medical applications.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is a feasibility study on the detection of gamma rays using a time - projection chamber (TPC) in liquid argon - nitrogen mixtures, especially the potential in the application of gamma - ray - nitrogen - resonance - absorption (GRNA). Specifically, the research focuses on how to improve the detection efficiency by separating the 1.75 MeV proton signal from the Compton electron signal. Since the 1.75 MeV proton is generated by the resonance absorption of 9.17 MeV gamma rays on the nitrogen nucleus, and non - resonant gamma rays mainly produce Compton electrons, being able to effectively distinguish these two particles is crucial for achieving high - precision GRNA imaging technology. In addition, the research also explores the influence of different nitrogen concentrations on the ionization signal in order to optimize the design parameters of the TPC and make it more suitable for GRNA applications in the medical and security fields. To verify the feasibility of this method, the researchers used 241Am as an alpha - particle source and 60Co as a gamma - ray source to simulate the behavior of 1.75 MeV protons in liquid argon - nitrogen mixtures. Based on these experimental data, the researchers predicted the ionization signals of 1.75 MeV protons at different nitrogen concentrations and analyzed the influence of factors such as electric field strength and nitrogen concentration on the signal collection efficiency. These results are of great significance for designing efficient GRNA detection systems.