Force-detected nuclear magnetic resonance: Recent advances and future challenges

M. Poggio,C. L. Degen
DOI: https://doi.org/10.1088/0957-4484/21/34/342001
2010-06-18
Abstract:We review recent efforts to detect small numbers of nuclear spins using magnetic resonance force microscopy. Magnetic resonance force microscopy (MRFM) is a scanning probe technique that relies on the mechanical measurement of the weak magnetic force between a microscopic magnet and the magnetic moments in a sample. Spurred by the recent progress in fabricating ultrasensitive force detectors, MRFM has rapidly improved its capability over the last decade. Today it boasts a spin sensitivity that surpasses conventional, inductive nuclear magnetic resonance detectors by about eight orders of magnitude. In this review we touch on the origins of this technique and focus on its recent application to nanoscale nuclear spin ensembles, in particular on the imaging of nanoscale objects with a three-dimensional (3D) spatial resolution better than 10 nm. We consider the experimental advances driving this work and highlight the underlying physical principles and limitations of the method. Finally, we discuss the challenges that must be met in order to advance the technique towards single nuclear spin sensitivity -- and perhaps -- to 3D microscopy of molecules with atomic resolution.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to use magnetic resonance force microscopy (MRFM) technology to detect a small number of nuclear spins, especially to achieve the detection of a single nuclear spin, and ultimately achieve three - dimensional atomic - resolution imaging of molecules**. Specifically, the paper reviews the progress in recent years in using magnetic resonance force microscopy (MRFM) to detect a small number of nuclear spins. MRFM is a scanning probe technique that relies on measuring the weak magnetic force between microscopic magnets and magnetic moments in the sample. Due to the progress in the manufacturing technology of ultrasensitive force detectors, the capabilities of MRFM have increased rapidly in the past decade, and its spin sensitivity has exceeded that of traditional inductive nuclear magnetic resonance detectors by about eight orders of magnitude. The main objectives of the paper include: 1. **Improve the sensitivity of nuclear spin detection**: Current technology is already able to detect as few as 100 nuclear spins, but further improvement in sensitivity is required to achieve the detection of a single nuclear spin. 2. **Achieve three - dimensional imaging at the nanoscale**: MRFM has been able to image nanoscale objects at a spatial resolution below 10 nanometers, and the future goal is to achieve three - dimensional atomic - resolution imaging of molecules. 3. **Overcome technical challenges**: In order to achieve higher sensitivity and resolution, a series of physical and technical challenges need to be solved, such as increasing the magnetic field gradient, reducing noise, and optimizing mechanical sensors. Through these efforts, MRFM is expected to become a high - resolution magnetic resonance imaging technology, applied in fields such as materials science, biology, and medicine, and is of particular significance for the imaging and analysis of complex biological structures.