How to Reliably Report the Overpotential of an Electrocatalyst
Siqi Niu,Siwei Li,Yunchen Du,Xijiang Han,Ping Xu
DOI: https://doi.org/10.1021/acsenergylett.0c00321
IF: 22
2020-03-17
ACS Energy Letters
Abstract:Article Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily.<a href="https://www.crossref.org/services/cited-by/"> Find more information about Crossref citation counts.</a>The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on<a href="https://help.altmetric.com/support/solutions/articles/6000060969-how-is-the-altmetric-attention-score-calculated"> the Altmetric Attention Score and how the score is calculated.</a>The intensifying energy crisis and detrimental environmental impacts have stimulated enormous interest in developing clean and renewable energy sources to decrease the dependence on traditional fossil energy.<a class="ref ref1 ref2 ref3 ref4" href="">(1−4)</a> Electrochemical water splitting is considered to be an important supplement of hydrogen energy, which contains two half reactions, namely, hydrogen evolution reaction (HER) at the cathode<a class="ref ref5" href="">(5)</a> and oxygen evolution reaction (OER) at the anode.<a class="ref ref6" href="">(6)</a> Operation of fuel cells that use hydrogen as the fuel involves hydrogen oxidation reaction (HOR) at the anode<a class="ref ref7" href="">(7)</a> and oxygen reduction reaction (ORR) at the cathode.<a class="ref ref8" href="">(8)</a> For the above-mentioned reactions, electrocatalysts are of great significance to effectively promote the reaction efficiency. In most cases, overpotential (η), the difference between the applied potential to deliver a certain current density and the thermodynamic potential value, is selected as the primary parameter to evaluate the activity of an electrocatalyst.<a class="ref ref9" href="">(9)</a>In general, electrochemical measurements are carried out in a three-electrode system, where a suitable reference electrode (RE) is applied according to the nature of the electrolyte solution. η is conventionally reported with reference to the reversible hydrogen electrode (RHE). The RHE conversion from the practically applied RE in most published literature is based on the simplified theoretical Nernst equation.<a class="ref ref19 ref20" href="">(19,20)</a> However, it should be noted that this correction method will lead to errors in the assessment of electrocatalytic activity. As shown in <a class="ref showTableEvent internalNav" href="#tbl1">Table </a><a class="ref showTableEvent internalNav" href="#tbl1">1</a>, the potential of one certain RE obtained through theoretical Nernst equation calculation and standard RE calibration using cyclic voltammetry (CV) can be varied by at most 30 mV, a value that can be used to show researchers so-called "great enhancement" in electrocatalytic activity, as the difference of η of one catalyst prepared from different methodologies but with same composition is typically in the range of tens of millivolts (mV). Moreover, with a similar experimental calibration process, the obtained calibrated value also differs case by case. Therefore, it is highly important to report the electrocatalytic activity, especially the η value, through a unified and reliable method.The value is obtained from experimental calibration process.The value is obtained from Nernst equation calculation.Herein, we have conducted standard experimental calibrations of distinct REs in a three-electrode system (<a class="internalNav" href="#fig1">Figure </a><a class="internalNav" href="#fig1">1</a>) in order to understand the difference between the measured and theoretical value and how the electrolyte conditions such as pH value and temperature will influence the measured overpotential. Pt foil (Aldrich) was selected as both the working electrode (WE) and counter electrode (CE). The electrolyte was saturated with high-purity hydrogen for at least 30 min before performing the electrode calibration. CV was carried out at a scan rate of 1 mV/s, and the average of the two interconversion point values was taken as the thermodynamic potential.<a class="ref ref21" href="">(21)</a> The commonly used Hg/HgO, Hg/Hg<sub>2</sub>Cl<sub>2</sub>, and Ag/AgCl REs were selected for alkaline, acidic, and neutral systems, respectively. Three parallel experiments were conducted for each electrode to eliminate accidental error. (The specific correction values for each experiment are listed in <a class="ext-link" href="/doi/suppl/10.1021/acsenergylett.0c00321/suppl_file/nz0c00321_si_001.pdf">Table S1</a>.)Figure 1. Experimental setup of the sealed standard three-elec <p>-Abstract Truncated-</p>
materials science, multidisciplinary,chemistry, physical,nanoscience & nanotechnology,energy & fuels,electrochemistry