Use of an Air Heating System at the Inlet to the Gas-Turbine Compressor as an Element of the Heat-Recovery System in a Combined-Cycle Power Plant

P. A. Berezinets,A. V. Shapkin
DOI: https://doi.org/10.1007/s10749-024-01756-4
2024-05-24
Power Technology and Engineering
Abstract:The use of an anti-icing air heating system (AHS) at the inlet to the compressor of a gas-turbine unit (GTU) at extremely low negative outdoor temperatures is analyzed. Due to its poor dynamic properties and the need to maintain the air temperature at the inlet to the compressor higher than –20°C, the AHS is continuously operated at an air temperature lower than 8°C. At air temperatures below –5°C, the delivery of the GTU compressor is decreased to meet the strength requirements to the flow part of the GTU. This reduces the power output of the steam turbine and the CCPP. To increase the delivery of the compressor in these cases, the air should be heated in the AHS. A beneficial effect is achieved when using the steam extracted from the steam turbine in the AHS. This decreases the heat loss in the condenser and increases the steam output of the heat recovery steam generator, the output of the steam turbine and the power unit as a whole. The increase in the output of the steam turbine exceeds its power underproduction because of the steam extraction for the AHS.