Performance of Commercially Open Refrigerated Showcases with and without Ice Storage—A Case Study

Kai-Shing Yang,Yun-Sheng Chao,Chia-Hsing Hsieh,Min-Lun Chai,Chi-Chuan Wang
DOI: https://doi.org/10.3390/pr9040683
IF: 3.5
2021-04-13
Processes
Abstract:This study examines the applicability of the ice storage systems in the small commercial refrigerated showcases through experimental analysis. R-404A is used as the working fluid and various influence of parameter settings and improvements, are discussed in details. In the ice storage system, the condenser is changed from air-cooling (refrigeration mode) to an immersion type that is placed in an ice storage tank, the corresponding condensing temperature and pressure are reduced appreciably. This increased the efficiency and can effectively reduce the peak power consumption. The reduction of the condensing temperature and pressure increased the coefficient of performance (COP) from 3.6 (refrigeration mode) to 6.35 (melting mode), effectively enhancing the refrigeration efficiency. The results indicated that the ice storage system could effectively increase the coefficient of performance from 3.6 to 6.35 during ice melting when compared to the conventional refrigeration system. It also can shift approximately 35% of the power during peak hours and lower the energy cost by USD$ 17.13 per month.
engineering, chemical
What problem does this paper attempt to address?