Experimental and numerical analysis of the critical heating strategy for hydronic heated snow melting airfield runway

Tan Yiqiu,Zhang Chi,Lv Huijie,Shi Hao,Xu Huining
DOI: https://doi.org/10.1016/j.applthermaleng.2020.115508
IF: 6.4
2020-09-01
Applied Thermal Engineering
Abstract:<p>Hydronic heated technology is an efficient and controllable method for airfield-runway snow removal. The heating strategy plays an important role in the application process. Nowadays, the users only consider the snow melting performance of pavement to determine the heating strategy, however the thermal stress of pavement is another considerable but missing aspect for the design of hydronic heated snow melting pavement. This paper investigated the thermal strain distribution of hydronic pavement through the digital-image-correlation and fiber Bragg grating strain sensors in a full-scale field experimental system. Thereafter, the thermal stress field of hydronic heated pavement was analyzed by a two-dimensional numerical model which contains the pavement temperature, thermal strain, and thermal stress distribution. Model validation results indicated that pavement temperature and thermal strain distribution between the experiment and the model were in good agreement. Numerical results showed that the remarkable compressive stress was observed near the hydronic pipe, and the maximum tensile stress appeared in the midpoint between two pipes at the depth of the pipes. The maximum thermal stress of pavement increased with fluid temperature but decreased with air temperature. The comparison results between the maximum thermal stress and mechanical strength of pavement show that the critical heating temperature increased with air temperature. The critical fluid temperature <sup>o</sup>C = 73 °C + 1.17 × ambient air temperature <sup>o</sup>C. The obtained results could ensure the security of hydronic heated snow-melting airfield-runway.</p>
energy & fuels,engineering, mechanical,thermodynamics,mechanics
What problem does this paper attempt to address?
The main problem this paper attempts to address is determining the critical heating strategy for hydronic heating airport runway de-icing systems under different weather conditions to ensure the safety and economy of the system's operation. Specifically, the study explores the thermal strain distribution and thermal stress characteristics of hydronic heating airport runways through experimental and numerical analysis, and proposes a method to determine the critical heating strategy for hydronic heating runways. The paper points out that currently, when designing hydronic heating de-icing systems, the heating strategy is usually determined only by considering the de-icing performance of the pavement, while ignoring the impact of thermal stress on the pavement. However, thermal stress is crucial to the safety of hydronic heating systems, especially under conditions of significant temperature changes, where thermal stress may cause pavement damage. Therefore, this study aims to fill this gap by analyzing the relationship between maximum thermal stress and pavement mechanical strength under different weather conditions, and proposes a set of safe heating strategies to ensure the efficient, stable, and safe operation of hydronic heating airport runway de-icing systems. Key points of the study include: 1. **Experimental Part**: Using a full-scale experimental system, the thermal strain distribution of the hydronic heating airport runway is monitored using Digital Image Correlation (DIC) technology and Fiber Bragg Grating (FBG) strain sensors. 2. **Numerical Simulation**: Establishing a 2D numerical model to analyze the temperature distribution, thermal strain, and thermal stress field of the hydronic heating airport runway. 3. **Results Analysis**: Investigating the impact of heating strategies and weather conditions on the maximum thermal stress, and determining the critical heating strategies under different weather conditions by comparing the maximum thermal stress with the pavement mechanical strength. In conclusion, the study finds that the critical heating temperature increases with the rise in ambient air temperature, with the specific relationship being: critical fluid temperature \( T_{\text{critical}} = 73 \,^\circ\text{C} + 1.17 \times \text{ambient air temperature} \,^\circ\text{C} \). These results contribute to the optimized design and operational management of hydronic heating de-icing systems.