Aerodynamic performance and wind-induced response of carbon fiber-reinforced polymer (CFRP) cables

Guanxu Long,Yamin Sun,Zhiqiang Shang,Xiaoyu Wang,Xingwei Xu,Tao Wang
DOI: https://doi.org/10.1038/s41598-024-59002-w
IF: 4.6
2024-04-10
Scientific Reports
Abstract:To study the aerodynamic performance and wind-induced response of carbon fiber-reinforced polymer (CFRP) cables, CFRP cable was designed by replacing a steel cable in a tied arch bridge based on stiffness, strength and area equivalent criteria, respectively. The aerodynamic performance and wind-induced response of CFRP cable and steel cable were studied and compared by computational fluid dynamics (CFD) model. Based on the computational results, optimal cable replacement criterion was proposed for CFRP cable to replace steel cable. In addition, surface modification was conducted by engrooving vertical symmetric (VS), vertical asymmetric (VA) and helical symmetric (HS) V-shaped grooves to improve the aerodynamic performance and wind-induced response of CFRP cable. Results showed that CFRP cables exhibited inferior aerodynamic performance and wind-induced response in most cases. However, CFRP cable based on stiffness equivalent criterion exhibited better aerodynamic performance and wind-induced vibration properties compared to the other two cable replacement criteria, thus is regarded as the optimal substitute for steel cable. In addition, HS grooves generated symmetric disturbances and caused approximately equivalent boundary layer separation delays uniformly and continuously along the cable length, thus exhibiting better effect in decreasing the reverse flow region, the maximum negative flow velocity, the vortex shedding frequency and the wind-induced vibration amplitude of CFRP cable. Hence, the stiffness equivalent criterion combined with surface modification with HS V-shaped grooves was proposed to replace steel cable with CFRP cable. This study can provide insights into the aerodynamic performance and wind-induced response of CFRP cable and instructions for cable replacement practice.
multidisciplinary sciences
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve This paper aims to study the aerodynamic performance and wind-induced response of carbon fiber reinforced polymer (CFRP) cables and compare them with traditional steel cables. Specifically, the paper attempts to address the following key issues: 1. **Aerodynamic Performance of CFRP Cables**: - Investigate the aerodynamic performance of CFRP cables at different wind speeds, including the distribution of flow velocity in the flow field, wind pressure distribution, and aerodynamic coefficients. - Compare the aerodynamic performance of CFRP cables and steel cables under the same conditions. 2. **Wind-Induced Response**: - Study the vibration characteristics of CFRP cables under wind load, including the time history curve of displacement response and the principal stress-loading step curve. - Compare the vibration amplitude and frequency of CFRP cables and steel cables under wind load. 3. **Optimal Replacement Criteria**: - Design CFRP cables based on three different replacement criteria: stiffness equivalence, strength equivalence, and area equivalence. - Determine the optimal criteria for replacing steel cables with CFRP cables through numerical simulations and experimental results. 4. **Effect of Surface Modification on Aerodynamic Performance**: - Study the impact of surface modification on aerodynamic performance and wind-induced response by engraving vertical symmetric (VS), vertical asymmetric (VA), and helical symmetric (HS) V-grooves on the surface of CFRP cables. - Determine the optimal surface modification scheme to improve the aerodynamic performance and wind-induced response of CFRP cables. ### Background and Significance Carbon fiber reinforced polymer (CFRP) has advantages such as high strength, light weight, corrosion resistance, and fatigue resistance. Particularly in bridge engineering, CFRP cables can extend maintenance cycles and increase the span capacity of suspension bridges. However, due to the lighter weight of CFRP cables, they are more sensitive to wind loads. Therefore, their aerodynamic performance and wind-induced response are critical issues that must be addressed before they can be widely applied in bridge engineering. ### Main Findings - **Aerodynamic Performance**: CFRP cables generally exhibit poor aerodynamic performance in most cases, but CFRP cables designed based on the stiffness equivalence criterion perform better. - **Wind-Induced Response**: CFRP cables based on the stiffness equivalence criterion outperform the other two replacement criteria in terms of wind-induced vibration characteristics. - **Surface Modification**: Helical symmetric (HS) V-grooves can uniformly and continuously delay boundary layer separation, reduce the reverse flow region, maximum negative flow velocity, vortex shedding frequency, and wind-induced vibration amplitude, showing the best effect. ### Conclusion This study proposes a scheme combining the stiffness equivalence criterion with surface-modified HS V-grooves to replace steel cables with CFRP cables. This research provides important theoretical basis and technical guidance for the application of CFRP cables in suspension bridges.