A Targeted, Bioinert LC-MS/MS Method for Sensitive, Comprehensive Analysis of Signaling Lipids

Stefanie Rubenzucker,Mailin-Christin Manke,Rainer Lehmann,Alice Assinger,Oliver Borst,Robert Ahrends
DOI: https://doi.org/10.1021/acs.analchem.4c01388
IF: 7.4
2024-05-26
Analytical Chemistry
Abstract:Signaling lipids are key players in cellular processes. Despite their importance, no method currently allows their comprehensive monitoring in one analytical run. Challenges include a wide dynamic range, isomeric and isobaric species, and unwanted interaction along the separation path. Herein, we present a sensitive and robust targeted liquid chromatography-mass spectrometry (LC-MS/MS) approach to overcome these challenges, covering a broad panel of 17 different signaling lipid classes. It...
chemistry, analytical
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop a high - performance liquid chromatography - mass spectrometry (LC - MS/MS) method capable of comprehensively monitoring signaling lipids. Specifically, the researchers faced the following challenges: 1. **Wide dynamic range**: The concentration range of signaling lipids in organisms is very wide, ranging from sub - nanomolar to high micromolar. 2. **Isomeric and isobaric species**: There are many molecules with similar structures but different functions in signaling lipids, which brings difficulties to the analysis. 3. **Nonspecific interactions during the separation process**: Some lipids contain free phosphate groups and are prone to interact with metal surfaces during the separation process, resulting in peak tailing and carry - over contamination. To solve these problems, the researchers developed a sensitive and robust LC - MS/MS method for 17 different classes of signaling lipids. This method has the following characteristics: - **Simple single - phase sample extraction**: Simplifies the sample pretreatment steps and improves the analysis efficiency. - **Bio - inert reversed - phase liquid chromatography**: The use of bio - inert column materials reduces the interaction between free phosphate groups and metal surfaces, improves the peak shape and reduces carry - over contamination. - **Target - oriented mass spectrometry analysis**: By optimizing the mass spectrometry parameters, high - sensitivity and high - repeatability detection of 388 signaling lipids was achieved. Through these improvements, the researchers successfully achieved a comprehensive analysis of signaling lipids in complex biological systems in a 20 - minute analysis run, providing a powerful tool for studying the role of signaling lipids in physiological and pathological processes.