Mepivacaine instillation for pain reduction during intrauterine device placement in nulliparous women: a double-blinded randomized trial

Niklas Envall,Karin Elgemark,Helena Kopp Kallner
DOI: https://doi.org/10.1016/j.ajog.2024.05.038
IF: 9.8
2024-05-25
American Journal of Obstetrics and Gynecology
Abstract:Background Fear of pain associated with intrauterine device placement has been identified as a significant barrier to the adoption of long-acting reversible contraception, contributing to lower utilization of the most effective reversible contraceptive methods. Objective To assess whether instillation of intrauterine mepivacaine before intrauterine device placement alleviates pain more effectively than a placebo. Study Design We conducted a multi-center, double-blind, randomized, placebo-controlled trial involving nulliparous women undergoing intrauterine device placement. An instillation of 10 mL of 20 mg/mL mepivacaine or 0.9 mg/mL sodium chloride was administrated through a hydrosonography catheter 2 minutes prior to intrauterine device placement. Pain scores were assessed using a 100 mm Visual Analog Scale at pre-specified time points. Primary outcome measured the difference in Visual Analog Scale pain scores between the intervention group and the placebo group during intrauterine device placement. Secondary outcomes included Visual Analog Scale pain scores at instillation and 10 minutes after placement, tolerability of the placement pain, as well as acceptability of the analgesia method. Results We enrolled 151 participants, with 76 assigned to the mepivacaine group and 75 to the placebo group. The mean VAS pain score during IUD placement showed a difference of 13.3 mm (95% CI 5.75-20.87; P <.001): the mepivacaine group had a mean of 53.9 mm (SD 22.8), while the placebo group had a mean of 67.2 mm (SD 22.4). After adjusting for each individual provider's impact, the difference in mean pain scores remained statistically significant (12.2 mm 95% CI 4.85-19.62; P <.001). A greater proportion of women in the intervention group reported tolerable pain during placement with 70/75 participants (93.3%) compared to 53/66 participants (80.3%) in the placebo group ( P =.021). Conclusion The intrauterine instillation of mepivacaine results in statistically significant reduction in pain score among nulliparous women during intrauterine device placement. Although the precise clinical impact of this pain reduction method remains uncertain, the observed reduction in pain score result in a higher proportion of women reporting tolerable pain. This finding and the high acceptance as a pain reduction method thereby suggests clinical relevance. Intrauterine instillation of mepivacaine is a possible strategy to increase IUD utilization, particularly among nulliparous women who are at high risk of unintended pregnancy.
obstetrics & gynecology
What problem does this paper attempt to address?