Radiomics Based on Multimodal MRI for the Differential Diagnosis of Benign and Malignant Breast Lesions
Qian Zhang,Yunsong Peng,Wei Liu,Jiayuan Bai,Jian Zheng,Xiaodong Yang,Lijuan Zhou
DOI: https://doi.org/10.1002/jmri.27098
IF: 4.4
2020-02-14
Journal of Magnetic Resonance Imaging
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Background</h3><p>MRI‐based radiomics has been used to diagnose breast lesions; however, little research combining quantitative pharmacokinetic parameters of dynamic contrast‐enhanced MRI (DCE‐MRI) and diffusion kurtosis imaging (DKI) exists.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>To develop and validate a multimodal MRI‐based radiomics model for the differential diagnosis of benign and malignant breast lesions and analyze the discriminative abilities of different MR sequences.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Study Type</h3><p>Retrospective.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Population</h3><p>In all, 207 female patients with 207 histopathology‐confirmed breast lesions (95 benign and 112 malignant) were included in the study. Then 159 patients were assigned to the training group, and 48 patients comprised the validation group.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Field Strength/Sequence</h3><p>T<sub>2</sub>‐weighted (T<sub>2</sub>W), T<sub>1</sub>‐weighted (T<sub>1</sub>W), diffusion‐weighted MR imaging (b‐values = 0, 500, 800, and 2000 seconds/mm<sup>2</sup>) and quantitative DCE‐MRI were performed on a 3.0T MR scanner. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Assessment</h3><p>Radiomics features were extracted from T<sub>2</sub>WI, T<sub>1</sub>WI, DKI, apparent diffusion coefficient (ADC) maps, and DCE pharmacokinetic parameter maps in the training set. Models based on each sequence or combinations of sequences were built using a support vector machine (SVM) classifier and used to differentiate benign and malignant breast lesions in the validation set. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Statistical Tests</h3><p>Optimal feature selection was performed by Spearman's rank correlation coefficients and the least absolute shrinkage and selection operator algorithm (LASSO). Receiver operating characteristic (ROC) curves were used to assess the diagnostic performance of the radiomics models in the validation set.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>The area under the ROC curve (AUC) of the optimal radiomics model, including T<sub>2</sub>WI, DKI, and quantitative DCE‐MRI parameter maps was 0.921, with an accuracy of 0.833. The AUCs of the models based on T<sub>1</sub>WI, T<sub>2</sub>WI, ADC map, DKI, and DCE pharmacokinetic parameter maps were 0.730, 0.791, 0.770, 0.788, and 0.836, respectively. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Data Conclusion</h3><p>The model based on radiomics features from T<sub>2</sub>WI, DKI, and quantitative DCE pharmacokinetic parameter maps has a high discriminatory ability for benign and malignant breast lesions. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Level of Evidence</h3><p>3</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Technical Efficacy Stage</h3><p>2</p></section>
radiology, nuclear medicine & medical imaging