Vehicle-Vehicle Energy Interaction Converter of Electric Vehicles: A Disturbance Observer Based Sliding Mode Control Algorithm

Rui Wang,Qiuye Sun,Chenghao Sun,Huaguang Zhang,Yonghao Gui,Peng Wang
DOI: https://doi.org/10.1109/tvt.2021.3105433
IF: 6.8
2021-10-01
IEEE Transactions on Vehicular Technology
Abstract:The electric vehicle technology is one of the most promising candidates to reduce fuel consumption and <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="7.683ex" height="2.509ex" style="vertical-align: -0.671ex;" viewBox="0 -791.3 3307.9 1080.4" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-72" x="0" y="0"></use> <use xlink:href="#MJMATHI-6D" x="451" y="0"></use> <use xlink:href="#MJMATHI-43" x="1330" y="0"></use><g transform="translate(2090,0)"> <use xlink:href="#MJMATHI-4F" x="0" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMAIN-32" x="1079" y="-213"></use></g></g></svg></span> emission. Although electric vehicles have been widely promoted by governments around the world, their development is seriously hampered due to charger unavailability and range anxiety. Based on this, this paper designs an energy interaction converter between two electric vehicles, which is controlled through disturbance observer based sliding mode control algorithm. For this converter, three main demands should be satisfied, i.e., high power density, weak source and constant power load. Therein, weak source whose minimum short circuit ratio (SCR) belongs to Jia et al., 2020 and Wang et al., 2020, is always called weak grid. Firstly, the equivalent impedance switching process is introduced to eliminate the impact of weak source. Meanwhile, the equivalent six channel interleaved floating dual boost converter is chosen to satisfy the high power density demand, whose generalized state-space function is further built to provide an indispensable preprocessing for following controller design. Moreover, in order to solve the problem regarding low frequency/sub-synchronous oscillation caused through constant power load feature regarding the energy consumption vehicle and weak source feature regarding the energy supply vehicle, a disturbance observer based sliding mode control algorithm is proposed through using generalized state-space function to provide standard DC power with both constant voltage and power. Furthermore, the proportional-resonant controller is proposed to solve the current sharing problem among six parallel channels, which reduces the heat loss and improves the service life of the device. Finally, simulation and experimental results verify the high performance of the proposed control algorithm.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-72" d="M21 287Q22 290 23 295T28 317T38 348T53 381T73 411T99 433T132 442Q161 442 183 430T214 408T225 388Q227 382 228 382T236 389Q284 441 347 441H350Q398 441 422 400Q430 381 430 363Q430 333 417 315T391 292T366 288Q346 288 334 299T322 328Q322 376 378 392Q356 405 342 405Q286 405 239 331Q229 315 224 298T190 165Q156 25 151 16Q138 -11 108 -11Q95 -11 87 -5T76 7T74 17Q74 30 114 189T154 366Q154 405 128 405Q107 405 92 377T68 316T57 280Q55 278 41 278H27Q21 284 21 287Z"></path><path stroke-width="1" id="MJMATHI-6D" d="M21 287Q22 293 24 303T36 341T56 388T88 425T132 442T175 435T205 417T221 395T229 376L231 369Q231 367 232 367L243 378Q303 442 384 442Q401 442 415 440T441 433T460 423T475 411T485 398T493 385T497 373T500 364T502 357L510 367Q573 442 659 442Q713 442 746 415T780 336Q780 285 742 178T704 50Q705 36 709 31T724 26Q752 26 776 56T815 138Q818 149 821 151T837 153Q857 153 857 145Q857 144 853 130Q845 101 831 73T785 17T716 -10Q669 -10 648 17T627 73Q627 92 663 193T700 345Q700 404 656 404H651Q565 404 506 303L499 291L466 157Q433 26 428 16Q415 -11 385 -11Q372 -11 364 -4T353 8T350 18Q350 29 384 161L420 307Q423 322 423 345Q423 404 379 404H374Q288 404 229 303L222 291L189 157Q156 26 151 16Q138 -11 108 -11Q95 -11 87 -5T76 7T74 17Q74 30 112 181Q151 335 151 342Q154 357 154 369Q154 405 129 405Q107 405 92 377T69 316T57 280Q55 278 41 278H27Q21 284 21 287Z"></path><path stroke-width="1" id="MJMATHI-43" d="M50 252Q50 367 117 473T286 641T490 704Q580 704 633 653Q642 643 648 636T656 626L657 623Q660 623 684 649Q691 655 699 663T715 679T725 690L740 705H746Q760 705 760 698Q760 694 728 561Q692 422 692 421Q690 416 687 415T669 413H653Q647 419 647 422Q647 423 648 429T650 449T651 481Q651 552 619 605T510 659Q484 659 454 652T382 628T299 572T226 479Q194 422 175 346T156 222Q156 108 232 58Q280 24 350 24Q441 24 512 92T606 240Q610 253 612 255T628 257Q648 257 648 248Q648 243 647 239Q618 132 523 55T319 -22Q206 -22 128 53T50 252Z"></path><path stroke-width="1" id="MJMATHI-4F" d="M740 435Q740 320 676 213T511 42T304 -22Q207 -22 138 35T51 201Q50 209 50 244Q50 346 98 438T227 601Q351 704 476 704Q514 704 524 703Q621 689 680 617T740 435ZM637 476Q637 565 591 615T476 665Q396 665 322 605Q242 542 200 428T157 216Q157 126 200 73T314 19Q404 19 485 98T608 313Q637 408 637 476Z"></path><path stroke-width="1" id="MJMAIN-32" d="M109 429Q82 429 66 447T50 491Q50 562 103 614T235 666Q326 666 387 610T449 465Q449 422 429 383T381 315T301 241Q265 210 201 149L142 93L218 92Q375 92 385 97Q392 99 409 186V189H449V186Q448 183 436 95T421 3V0H50V19V31Q50 38 56 46T86 81Q115 113 136 137Q145 147 170 174T204 211T233 244T261 278T284 308T305 340T320 369T333 401T340 431T343 464Q343 527 309 573T212 619Q179 619 154 602T119 569T109 550Q109 549 114 549Q132 549 151 535T170 489Q170 464 154 447T109 429Z"></path></defs></svg>
telecommunications,engineering, electrical & electronic,transportation science & technology
What problem does this paper attempt to address?