Observational Assessment of Pre-Analytical Errors in Request Format and Phlebotomy Practice in Hematology Tests at Hawassa University Comprehensive Specialized Hospital in Sidama Zone, Southern Ethiopia
Bedasa Addisu,Amanuel Kelem,Agete Hirigo
DOI: https://doi.org/10.2147/plmi.s439227
2023-12-20
Pathology and Laboratory Medicine International
Abstract:Bedasa Addisu, 1 Amanuel Kelem, 2 Agete Tadewos Hirigo 3 1 Department of Medical Laboratory Science, College of Medicine and Health Sciences, Debre Berhan University, Debre Berhan, Amhara, Ethiopia; 2 Department of Medical Laboratory Sciences, Asrat Woldeyes Health Science Campus, Debre Berhan University, Debre Berhan, Ethiopia; 3 School of Medical Laboratory Science, College of Medicine and Health Sciences, Hawassa University, Hawassa, Ethiopia Correspondence: Bedasa Addisu, Department of Medical Laboratory Science, College of Medicine and Health Sciences, Debre Berhan University, PO Box 445, Debre Berhan, Ethiopia, Tel +251912496933, Email Background: The significance of quality in laboratories necessitates the implementation of comprehensive quality management throughout the entire laboratory process, encompassing the pre-analytical to post-analytical phases. The pre-analytical phase, which plays a crucial role in laboratory services, is particularly significant, as it is responsible for approximately 70% of errors. Enhancing the quality of the pre-analytical phase is essential to ensure the effectiveness of laboratory services and safeguard patient safety. Objective: The objective of this study was to assess errors made in the request format and phlebotomy procedures during the collection of blood samples for hematology laboratory tests between April and June 2019. Methods: A cross-sectional study was carried out at Hawassa University College of Medicine and Health Sciences on 393 samples with their respective request forms. The study employed a systematic sampling technique and utilized well-structured checklists to gather all the necessary data for hematology laboratory tests, including a thorough evaluation of the requested form. Data analysis was performed using the Statistical Package for Social Sciences (SPSS) software version 21. Results: A total of 393 hematological samples from their respective request forms were analyzed in this study. Generally, the request forms did not contain all the necessary information, and each form had at least one error. The study also revealed the occurrence of pre-analytical errors in phlebotomy practice. These errors included prolonged tourniquet application (26.2%), improper identification (22.9%), inadequate cleaning of the vein puncture site (62.8%), unsafe needle removal and blood transfer to test tubes (6.6%), and improper mixing of collected blood samples (41.5%). Conclusion: The findings of this study revealed a substantial occurrence of pre-analytical errors in the hematology laboratory department. Therefore, it is crucial to prioritize the correct execution and utilization of phlebotomy procedures as well as request format to enhance quality assurance in hematology laboratory units. Keywords: pre-analytical errors, phlebotomy practices, laboratory quality management Laboratory diagnostics plays a crucial role in clinical decision-making, providing valuable support in the disease prevention, diagnosis, and therapeutic monitoring of a wide range of health problems. It is estimated that around 60–70% of the most critical medical decisions heavily rely on laboratory test results. Consequently, the utilization of laboratory diagnostics becomes imperative to guarantee the reliability and accuracy of outcomes derived from clinical laboratories. 1–3 Despite significant advancements in scientific innovations aimed at enhancing the laboratory environment and ensuring the accuracy of clinical laboratory test results, errors have continued to persist. 4 These errors can be categorized into pre-analytical, analytical, and post-analytical errors, with pre-analytical errors being the most prevalent and posing a significant risk to patient diagnosis and treatment. 3,4 The pre-analytical phase of the laboratory diagnostic process is susceptible to errors that can occur from the moment a test is ordered by a physician until the sample is prepared for analysis. 3 These errors are responsible for a significant proportion of the errors encountered during the entire process, with up to 70% of them occurring during sample collection, handling, transportation, and storage. 5,6 The occurrence of pre-analytical errors before sample collection can be attributed to various factors. Notably, the incomplete request format information form plays a crucial role in this regard, as it lacks essential details such as the physician's name, patient misidentification, and the requested test format. 3,6 These omissions significantly contribute to the overall prevalence of pre-analytical errors. In addition, the incorrect labeling of specimen collection materials furthe -Abstract Truncated-