Multi-Channel Soft Dry Electrodes for Electrocardiography Acquisition in the Ear Region

Patrick van der Heijden,Camille Gilbert,Samira Jafari,Mattia Alberto Lucchini
DOI: https://doi.org/10.3390/s24020420
IF: 3.9
2024-01-11
Sensors
Abstract:In-ear acquisition of physiological signals, such as electromyography (EMG), electrooculography (EOG), electroencephalography (EEG), and electrocardiography (ECG), is a promising approach to mobile health (mHealth) due to its non-invasive and user-friendly nature. By providing a convenient and comfortable means of physiological signal monitoring, in-ear signal acquisition could potentially increase patient compliance and engagement with mHealth applications. The development of reliable and comfortable soft dry in-ear electrode systems could, therefore, have significant implications for both mHealth and human–machine interface (HMI) applications. This research evaluates the quality of the ECG signal obtained with soft dry electrodes inserted in the ear canal. An earplug with six soft dry electrodes distributed around its perimeter was designed for this study, allowing for the analysis of the signal coming from each electrode independently with respect to a common reference placed at different positions on the body of the participants. An analysis of the signals in comparison with a reference signal measured on the upper right chest (RA) and lower left chest (LL) was performed. The results show three typical behaviors for the in-ear electrodes. Some electrodes have a high correlation with the reference signal directly after inserting the earplug, other electrodes need a settling time of typically 1–3 min, and finally, others never have a high correlation. The SoftPulseTM electrodes used in this research have been proven to be perfectly capable of measuring physiological signals, paving the way for their use in mHealth or HMI applications. The use of multiple electrodes distributed in the ear canal has the advantage of allowing a more reliable acquisition by intelligently selecting the signal acquisition locations or allowing a better spatial resolution for certain applications by processing these signals independently.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a reliable and comfortable in - ear multi - channel soft dry - electrode system for obtaining electrocardiogram (ECG) signals. Specifically, the research aims to evaluate the performance of these soft dry electrodes in the ear canal and explore their potential in mobile health (mHealth) and human - machine interface (HMI) applications. ### Specific description of the problem 1. **Improve user compliance and comfort**: - Researchers hope to increase patients' compliance and participation in mHealth applications by providing a non - invasive and user - friendly method for physiological signal monitoring. 2. **Verify electrode performance**: - Evaluate the signal quality of soft dry electrodes in the ear canal, especially compared with the performance of traditional thoracic electrodes (such as the standard II - lead ECG between the right arm RA and the left leg LL). 3. **Explore the advantages of multi - channel signals**: - Investigate whether multiple electrodes distributed in the ear canal can provide more reliable signal acquisition or improve the spatial resolution of certain applications by independently processing these signals. 4. **Adapt to different application scenarios**: - Study different electrode configurations to reflect various application scenarios that may involve a second electrode in other parts of the body, such as between the ears, inside the ear, etc. ### Experimental design To achieve the above goals, researchers designed an earplug with 6 soft dry electrodes and inserted it into the ear canal. Each electrode can be independently connected to a common reference point to obtain differential signals. The experiment includes the following measurement configurations: - **Between the ear and the left leg (LL)**: Measure the signals between each ear and LL. - **Between the ears**: Measure the signals between the two ears. - **Inside the ear**: Measure the signals at different positions within the same ear. ### Results The research results show that the behavior of different electrodes exhibits three typical characteristics: 1. **Immediate high correlation**: Some electrodes show a high correlation with the reference signal immediately after the earplug is inserted. 2. **Require stabilization time**: Other electrodes require a stabilization time of 1 - 3 minutes to achieve high correlation. 3. **Always low correlation**: There are also some electrodes that can never achieve high correlation. In addition, the electrodes at the top position (northern side) generally show a higher correlation, while the electrodes at the bottom position (southern side) perform poorly. ### Conclusion The research shows that SoftPulseTM electrodes can effectively measure physiological signals, paving the way for future mHealth and HMI applications. By using multiple electrodes distributed in the ear canal, the signal acquisition location can be selected more intelligently or the spatial resolution of certain applications can be improved. ### Formula example During the data processing, researchers used a Butterworth filter for signal pre - processing: \[ y(t)=\text{filtfilt}(x(t), b, a) \] where \(y(t)\) is the filtered signal, \(x(t)\) is the original signal, and \(b\) and \(a\) are the numerator and denominator coefficients of the filter respectively. The filter parameters are set as follows: - The low - pass filter cutoff frequency \(f_c = 30\) Hz - The high - pass filter cutoff frequency \(f_c = 0.3\) Hz These filters are used to reduce phase distortion and extract useful signal components.