Spatially Resolved Defect Characterization and Fidelity Assessment for Complex and Arbitrary Irregular 3D Printing Based on 3D P-OCT and GCode

Bowen Fan,Shanshan Yang,Ling Wang,Mingen Xu
DOI: https://doi.org/10.3390/s24113636
IF: 3.9
2024-06-05
Sensors
Abstract:To address the challenges associated with achieving high-fidelity printing of complex 3D bionic models, this paper proposes a method for spatially resolved defect characterization and fidelity assessment. This approach is based on 3D printer-associated optical coherence tomography (3D P-OCT) and GCode information. This method generates a defect characterization map by comparing and analyzing the target model map from GCode information and the reconstructed model map from 3D P-OCT. The defect characterization map enables the detection of defects such as material accumulation, filament breakage and under-extrusion within the print path, as well as stringing outside the print path. The defect characterization map is also used for defect visualization, fidelity assessment and filament breakage repair during secondary printing. Finally, the proposed method is validated on different bionic models, printing paths and materials. The fidelity of the multilayer HAP scaffold with gradient spacing increased from 0.8398 to 0.9048 after the repair of filament breakage defects. At the same time, the over-extrusion defects on the nostril and along the high-curvature contours of the nose model were effectively detected. In addition, the finite element analysis results verified that the 60-degree filling model is superior to the 90-degree filling model in terms of mechanical strength, which is consistent with the defect detection results. The results confirm that the proposed method based on 3D P-OCT and GCode can achieve spatially resolved defect characterization and fidelity assessment in situ, facilitating defect visualization and filament breakage repair. Ultimately, this enables high-fidelity printing, encompassing both shape and function.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper primarily addresses the challenges in the 3D bioprinting process, particularly the issue of high-fidelity printing of complex 3D bionic models. It proposes a spatially resolved defect characterization and fidelity evaluation method based on 3D Printing-Associated Optical Coherence Tomography (3D P-OCT) and GCode information. Specifically, the research methods in the paper include the following aspects: 1. **Background Introduction**: 3D printing technology is widely used in medical, aerospace, and educational fields, but it still faces many challenges in complex 3D bioprinting, such as printing defects and low structural fidelity. 2. **Research Objectives**: To address the above issues, this study aims to develop a method that can achieve spatially resolved defect characterization and fidelity evaluation to improve the quality and stability of 3D printing. 3. **Methodology**: - **3D P-OCT System**: A self-developed 3D P-OCT system is used, integrating a 3D bioprinter with optical coherence tomography technology for real-time monitoring of the printing process. - **GCode Information Utilization**: Target model images are generated based on GCode information and compared with the actual printing results for analysis. - **Defect Characterization Map**: By comparing the target model images and reconstructed model images, a defect characterization map is generated to achieve defect detection, visualization, and fidelity evaluation. - **Repair Strategy**: Based on the information provided by the defect characterization map, secondary printing instructions are automatically generated to repair defects such as filament breakage. 4. **Validation Experiments**: The effectiveness of the method is validated through experiments with different models (such as multi-layer gradient-spaced hydroxyapatite scaffolds, nose models, and ear models), printing paths, and materials (such as hydroxyapatite HAP, silicone, and polycaprolactone PCL). 5. **Results Presentation**: The results show that after repairing the filament breakage defect, the fidelity of the multi-layer hydroxyapatite scaffold increased from 0.8398 to 0.9048. Additionally, over-extrusion defects at the nostrils of the nose model and along the high-curvature contours were effectively detected. In summary, the method proposed in this study can effectively address defect issues in the 3D bioprinting process, improving the fidelity and functionality of printed structures, and is of great significance for advancing 3D bioprinting technology.