A solenoidal electron spectrometer for a precision measurement of the neutron $β$-asymmetry with ultracold neutrons

B. Plaster,R. Carr,B.W. Filippone,D. Harrison,J. Hsiao,T.M. Ito,J. Liu,J.W. Martin,B. Tipton,J. Yuan
DOI: https://doi.org/10.1016/j.nima.2008.07.143
2008-06-13
Abstract:We describe an electron spectrometer designed for a precision measurement of the neutron $\beta$-asymmetry with spin-polarized ultracold neutrons. The spectrometer consists of a 1.0-Tesla solenoidal field with two identical multiwire proportional chamber and plastic scintillator electron detector packages situated within 0.6-Tesla field-expansion regions. Select results from performance studies of the spectrometer with calibration sources are reported.
Nuclear Experiment
What problem does this paper attempt to address?