Determination of squalene in functional food by gas chromatography and high-performance liquid chromatography

Zou Hai-mi
Abstract:Objective To develop methods for determination of squalene in functional food by gas chromatography(GC) and high performance liquid chromatography(HPLC). Methods The samples were ultrasonically extracted with hexane and squalane was used as the internal standard. The operation conditions for GC were: column: SPB-5(30 m×0.53 mm×0.5 μm); injector temperature: 300℃; the fire ionization detector temperature: 300℃; the column temperature: 280℃; the flow rate of carrier was 2 ml/min. Analytical conditions for HPLC were: column: C18 5 μm, 250×4.6 mm, methanol as the mobile phase; detection wavelength: 210 nm; temperature: 30℃. Results The linear correlation coefficient of the GC method was 0.999 9 with in the range of 0.002~0.2 μg. The detection limit of the method was 0.62 ng, with a relative standard deviation of 1.99% and the recovery rate ranging from 95.76% to 100.9%. The linear correlation coefficient for the HPLC method was 0.999 7 with in the range of 0.10 to 10.00 μg, with a relative standard deviation of 2.22% and the recovery rate ranging from 100.0% to 106.5%. Conclusion The gas chromatography method is more sensitive, faster and lower in cost than the high performance liquid chromatographic method for the determination of squalene in functional food.