Abstract:In the 80's, biomechanicians were asked to work on Computer Aided Surgery applications since orthopaedic surgeons were looking for numerical tools able to predict risks of fractures. More recently, biomechanicians started to address soft tissues arguing that most of the human body is made of such tissues that can move as well as deform during surgical gestures [1]. An intra-operative use of a continuous Finite Element (FE) Model of a given tissue mainly faces two problems: (1) the numerical simulations have to be "interactive", i.e. sufficiently fast to provide results during surgery (which can be a strong issue in the context of hyperelastic models for example) and (2) during the intervention, the surgeon needs a device that can be used to provide to the model an estimation of the patient-specific constitutive behaviour of the soft tissues. This work proposes an answer to the second point, with the design of a new aspiration device aiming at characterizing the in vivo constitutive laws of human soft tissues. The device was defined in order to permit sterilization as well an easy intra-operative use.
Medical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to measure the constitutive behavior of human soft tissues in real - time and accurately during the surgical process**, in order to provide patient - specific soft tissue mechanical models for Computer - Aided Surgery (CAS). Specifically, the paper focuses on two main issues: 1. **Real - time performance of numerical simulation**: In order to use the Finite Element (FE) model for prediction during the surgical process, the numerical simulation must be fast enough to provide real - time results. This is a challenge for complex models such as hyperelastic models. 2. **Practicality of intraoperative devices**: A device that can be used during the operation and provide an estimate of the patient - specific soft tissue constitutive behavior is required during the surgical process. To solve the second problem, the author designed a new **pipette device** to characterize the **in - vivo constitutive law** of human soft tissues. This device is designed to meet the strict requirements during the operation, such as sterility and ease of operation. ### Key content summary - **Background**: - In the 1980s, biomechanics experts began to study computer - aided surgery applications, especially for the prediction of fracture risk. - In recent years, biomechanics experts have begun to focus on soft tissues because most of the human body is composed of these soft tissues that can move and deform. - **Methods**: - Use the **pipette experiment** to measure the mechanical properties of soft tissues. By creating a small negative pressure (several tens of millibars) inside a transparent cylinder, a bulge is created in the soft tissue, and this bulge is photographed with a digital camera. - A two - dimensional axisymmetric finite - element model was established to fit the experimental data. It is assumed that the tissue sample is a thick disc with a radius of \(a\) and a thickness of \(h\); the pipette is described as a rigid hollow cylinder with internal and external radii of \(R_i\) and \(R_e\) respectively. - **Results**: - The experimental results show that the finite - element simulation is in good agreement with the actual measurement data. - For human forearm skin, a two - parameter Mooney - Rivlin strain - energy function is assumed: \[ W = a_1 (I_1 - 3)+a_3 (I_1 - 3)^3 \] where \(a_1\) and \(a_3\) are material constants, and \(I_1\) is the first invariant of the Cauchy strain tensor. - By minimizing the difference between the measured and simulated values, the optimal material constants \(a_1 = 2\) and \(a_3 = 400\) were determined. - **Conclusions**: - The pipette technique is a robust measurement method suitable for intraoperative use. - Combined with the optimization scheme based on the finite - element method, the nonlinear material model can be determined through the inversion process. - The current inversion process is time - consuming, but it can be significantly shortened through improvement to achieve "interactive time" use. In conclusion, this paper proposes an innovative method that combines the pipette experiment and finite - element simulation to solve the problem of real - time measurement of soft tissue constitutive behavior during the operation.