Hot Wires and Film Boiling: Another Look at Carbonyl Formation in Electronic Cigarettes

Soha Talih,Rola Salman,Ebrahim Karam,Mario El-Hourani,Rachel El-Hage,Nareg Karaoghlanian,Ahmad El-Hellani,Najat Saliba,Alan Shihadeh
DOI: https://doi.org/10.1021/acs.chemrestox.0c00196
2020-07-08
Chemical Research in Toxicology
Abstract:Electronic cigarettes (ECIGs) are a class of tobacco products that emit a nicotine-containing aerosol by heating and vaporizing a liquid. Apart from initiating nicotine addiction in nonsmokers, a persistent concern about these products is that their emissions often include high levels of carbonyl species, toxicants thought to cause most noncancer pulmonary diseases in smokers. This study examined whether the phenomenon of film boiling can account for observations of high carbonyl emissions under certain operating conditions and, if so, whether film boiling theory can be invoked to predict conditions where high carbonyl emissions are likely. We measured the critical heat flux for several common heating materials and liquids and carbonyl emissions for several ECIG types while varying the power. We found that emissions rise drastically whenever the power exceeds the value corresponding to the critical heat flux. While limiting the heat flux to below this threshold can greatly reduce carbonyl exposure, ECIG manufacturer operating instructions often exceed it. Product regulations that limit heat flux may reduce the public health burden of electronic cigarette use.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.chemrestox.0c00196?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.chemrestox.0c00196</a>.Materials and Methods section, EScribe Suite validation, ECIG features and dimensions, thermodynamic properties of PG and VG, schematic of the setup used to verify the voltage set and measured by EScribe. EScribe vs DAQ voltage measurements, schematic of the setup used to verify the resistance measured by EScribe. EScribe vs milli-Ω meter resistance measurements, EScribe temperature validation setup, submerged wire conditions and results, aerosol generation conditions and results, liquid vaporized and formaldehyde yields vs <i>q</i>″, and critical heat flux determination (<a class="ext-link" href="/doi/suppl/10.1021/acs.chemrestox.0c00196/suppl_file/tx0c00196_si_001.pdf">PDF</a>)Boiling regimes observed on a nickel wire submerged in a saturated PG solution (<a class="ext-link" href="/doi/suppl/10.1021/acs.chemrestox.0c00196/suppl_file/tx0c00196_si_002.mp4">MP4</a>)This article has not yet been cited by other publications.
What problem does this paper attempt to address?