Composable Microfluidic Plates (cPlate): A Simple and Scalable Fluid Manipulation System for Multiplexed Enzyme-Linked Immunosorbent Assay (ELISA)

Ziyi He,Justin Huffman,Kathrine Curtin,Krista L. Garner,Elizabeth C. Bowdridge,Xiaojun Li,Timothy R. Nurkiewicz,Peng Li
DOI: https://doi.org/10.1021/acs.analchem.0c03651
IF: 7.4
2020-12-16
Analytical Chemistry
Abstract:Enzyme-linked immunosorbent assay (ELISA) is the gold standard method for protein biomarkers. However, scaling up ELISA for multiplexed biomarker analysis is not a trivial task due to the lengthy procedures for fluid manipulation and high reagent/sample consumption. Herein, we present a highly scalable multiplexed ELISA that achieves a similar level of performance to commercial single-target ELISA kits as well as shorter assay time, less consumption, and simpler procedures. This ELISA is enabled by a novel microscale fluid manipulation method, composable microfluidic plates (cPlate), which are comprised of miniaturized 96-well plates and their corresponding channel plates. By assembling and disassembling the plates, all of the fluid manipulations for 96 independent ELISA reactions can be achieved simultaneously without any external fluid manipulation equipment. Simultaneous quantification of four protein biomarkers in serum samples is demonstrated with the cPlate system, achieving high sensitivity and specificity (∼ pg/mL), short assay time (∼1 h), low consumption (∼5 μL/well), high scalability, and ease of use. This platform is further applied to probe the levels of three protein biomarkers related to vascular dysfunction under pulmonary nanoparticle exposure in rat's plasma. Because of the low cost, portability, and instrument-free nature of the cPlate system, it will have great potential for multiplexed point-of-care testing in resource-limited regions.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c03651?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c03651</a>.Experimental details, cPlate device design, loading pattern, performance of uncoated/patterned well plates, volume consistency after washing, response curves for plasma proteins, correlations between cPlate and 96-well ELISA, and comparison between conventional ELISA and cPlate ELISA (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c03651/suppl_file/ac0c03651_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?