Predictors of atrial fibrillation after embolic stroke of undetermined source in patients with implantable loop recorders

Fabienne Kreimer,Assem Aweimer,Ibrahim El-Battrawy,Adnan Labedi,Ruth Schneider,Arash Haghikia,Andreas Mügge,Michael Gotzmann
DOI: https://doi.org/10.1007/s10072-024-07548-y
2024-04-25
Neurological Sciences
Abstract:Abstract Background In patients with embolic stroke of undetermined source (ESUS), underlying subclinical atrial fibrillation (AF) is often suspected. Previous studies identifying predictors of AF have been limited in their ability to diagnose episodes of AF. Implantable loop recorders enable prolonged, continuous, and therefore more reliable detection of AF. The aim of this study was to identify clinical and ECG parameters as predictors of AF in ESUS patients with implantable loop recorders. Methods 101 ESUS patients who received an implantable loop recorder between 2012 and 2020 were included in this study. Patients were followed up regularly on a three-monthly outpatient interval. Results During a mean follow-up of 647 ± 385 days, AF was detected in 26 patients (26%). Independent risk factors of AF were age ≥ 60 years (HR 2.753, CI 1.129–6.713, p = 0.026), P-wave amplitude in lead II ≤ 0.075 mV (HR 3.751, CI 1.606–8.761, p = 0.002), and P-wave duration ≥ 125 ms (HR 4.299, CI 1.844–10.021, p < 0.001). In patients without risk factors, the risk of developing AF was 16%. In the presence of one risk factor, the probability increased only slightly to 18%. With two or three risk factors, the risk of AF increased to 70%. Conclusion AF was detected in about one in four patients after ESUS in this study. A comprehensive evaluation involving multiple parameters and the existence of multiple risk factors yields the highest predictive accuracy for detecting AF in patients with ESUS.
neurosciences,clinical neurology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to identify the clinical and electrocardiogram (ECG) parameter predictors of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS) under the monitoring of implantable loop recorder (ILR). Specifically, the study aims to determine which clinical features and ECG indicators can effectively predict the occurrence of AF in ESUS patients through long - term follow - up and by using the continuous monitoring data provided by ILR. This helps to optimize the management and prevention strategies for ESUS patients, especially for those patients who may have an increased risk of stroke recurrence due to AF. ### Research Background In ischemic strokes of undetermined cause (about 20 - 40% of ischemic strokes), occult AF is often suspected as an underlying cause. Current guidelines recommend at least 24 - hour ECG monitoring after ischemic stroke to rule out AF, but the optimal monitoring time and method have not been determined. Implantable loop recorder (ILR) has been proven to have high sensitivity and specificity in detecting AF because it can provide long - term and continuous ECG monitoring. ### Research Purpose The main purpose of this study is to identify the clinical and ECG parameters related to the occurrence of AF in ESUS patients with ILR implanted. These parameters will help to more accurately predict the risk of AF in ESUS patients, thereby guiding clinical decision - making and preventive measures. ### Main Findings 1. **Age**: ≥60 years old is an independent risk factor for AF (HR 2.753, CI 1.129–6.713, p = 0.026). 2. **P - wave amplitude in lead II**: ≤0.075 mV is an independent risk factor for AF (HR 3.751, CI 1.606–8.761, p = 0.002). 3. **P - wave duration**: ≥125 ms is an independent risk factor for AF (HR 4.299, CI 1.844–10.021, p < 0.001). ### Risk Stratification - The incidence of AF in patients without risk factors is 16%. - The incidence of AF in patients with one risk factor is 18%. - The incidence of AF in patients with two or three risk factors significantly increases to 70%. ### Conclusion In ESUS patients, about one - fourth of the patients were diagnosed with AF during the follow - up period. Comprehensive assessment of multiple parameters and the presence of multiple risk factors can improve the predictive accuracy of AF detection. This provides an important reference basis for the management and prevention of ESUS patients.