Non-Destructive Testing of Carbon Fiber-Reinforced Plastics (CFRPs) Using a Resonant Eddy Current Sensor

Ming Ma,Shiyu Liu,Ronghua Zhang,Qiong Zhang,Yi Wu,Bailiang Chen
DOI: https://doi.org/10.3390/s24113449
IF: 3.9
2024-05-27
Sensors
Abstract:Eddy current testing (ECT) is commonly used for the detection of defects inside metallic materials. In order to achieve the effective testing of CFRP materials, increasing the operating frequency or improving the coil structure is a common method used by researchers. Higher or wider operating frequencies make the design of the ADC's conditioning circuit complex and difficult to miniaturize. In this paper, an LC resonator based on inductance-to-digital converters (LDCs) is designed to easily detect the resonant frequency response to the state of the material under test. The reasonableness of the coil design is proven by simulation. The high signal-to-noise ratio (SNR) and detection sensitivity of the LC resonator are demonstrated through comparison experiments involving multiple probes. The anti-interference capability of the LC resonator in CFRP defect detection is demonstrated through various interference experiments.
engineering, electrical & electronic,instruments & instrumentation,chemistry, analytical
What problem does this paper attempt to address?
The paper primarily addresses the issue of non-destructive testing of carbon fiber reinforced plastic (CFRP) materials, particularly using resonant eddy current sensors. Specifically, the paper focuses on the following points: 1. **Background and Challenges**: Eddy current testing (ECT) technology is typically used for detecting internal defects in metallic materials. However, for emerging materials like CFRP, due to its much lower electrical conductivity compared to metals and its anisotropy, traditional eddy current testing methods face challenges. 2. **Solution**: The paper proposes a novel non-destructive testing method based on an LC resonator and an inductance-to-digital converter (LDC). By introducing a capacitor into the eddy current sensor to form an LC resonant circuit, effective detection of CFRP materials can be achieved at lower operating frequencies, thereby reducing background noise interference and improving the signal-to-noise ratio (SNR) and detection sensitivity. 3. **Design Advantages**: Compared to existing resonant eddy current detection methods, this method does not fix the probe's excitation frequency near its self-resonant frequency but instead creates an LC resonator by introducing a capacitor. This ensures that the coil's operating frequency is significantly lower than its self-resonant frequency, effectively reducing the impact of potential background noise. Additionally, through reasonable coil design, the induction distance of the LC resonator is increased, and the self-resonant frequency of the coil is raised, maximizing the operating frequency of the LC resonator and enhancing the detection capability for surface defects. 4. **Experimental Validation**: The paper also validates the rationality and superiority of the proposed LC resonator in CFRP defect detection through simulations and comparative experiments, including high signal-to-noise ratio, high detection sensitivity, and strong anti-interference capability. In summary, this research aims to develop an efficient and stable eddy current testing technology to address the specific challenges in the detection of CFRP materials.