The Stochastic Dynamics of an Array of Atomic Force Microscopes in a Viscous Fluid

M.T. Clark,M.R. Paul
DOI: https://doi.org/10.1016/j.ijnonlinmec.2006.10.003
2006-08-29
Abstract:We consider the stochastic dynamics of an array of two closely spaced atomic force microscope cantilevers in a viscous fluid for use as a possible biomolecule sensor. The cantilevers are not driven externally, as is common in applications of atomic force microscopy, and we explore the stochastic cantilever dynamics due to the constant buffeting of fluid particles by Brownian motion. The stochastic dynamics of two adjacent cantilevers are correlated due to long range effects of the viscous fluid. Using a recently proposed thermodynamic approach the hydrodynamic correlations are quantified for precise experimental conditions through deterministic numerical simulations. Results are presented for an array of two readily available atomic force microscope cantilevers. It is shown that the force on a cantilever due to the fluid correlations with an adjacent cantilever is more than 3 times smaller than the Brownian force on an individual cantilever. Our results indicate that measurements of the correlations in the displacement of an array of atomic force microscopes can detect piconewton forces with microsecond time resolution.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to detect the real - time dynamics of single molecules and improve the force sensitivity and time resolution by measuring the stochastic dynamics of atomic force microscope (AFM) cantilever arrays in viscous fluids?** Specifically, the authors studied the stochastic dynamics of two adjacent AFM cantilevers in viscous fluids due to Brownian motion. In traditional AFM applications, the cantilevers are usually externally driven, while this paper explores the random motion of cantilevers in fluids without external driving. Due to the long - range effect of the fluid, the stochastic dynamics between two adjacent cantilevers are correlated. The authors used a recently proposed thermodynamic method to quantify this hydrodynamic correlation through deterministic numerical simulations. ### Main problems: 1. **Improve force sensitivity**: The Brownian force on a single cantilever is relatively large (about 74 pN), which limits the ability to detect biomolecular dynamics. By measuring the displacement correlation between two cantilevers, the noise level can be significantly reduced, thereby improving the force sensitivity. 2. **Improve time resolution**: The authors hope to use the cantilever array to achieve a time resolution at the microsecond level, so as to be able to measure the intermolecular interaction forces in real - time (such as protein conformational changes or substrate metabolism, etc.). These forces are usually on the order of 10s pN, and the time scale is 10s milliseconds. ### Results and conclusions: - By measuring the displacement correlation between two cantilevers, a force less than three times the Brownian force of a single cantilever (about 22 pN) can be detected, and a force on the order of pN can be measured at a kHz frequency resolution. - The research shows that when the maximum separation distance is 2 µm, the noise is reduced by four times, which provides an important theoretical basis for future single - molecule experiments. ### Formula summary: - Brownian force formula: \[ F_{11}=\sqrt{k_B T k} \] where \(k_B\) is the Boltzmann constant, \(T\) is the absolute temperature, and \(k\) is the spring constant of the cantilever. - Force sensitivity formula: \[ F_{12}=k\left|\langle x_1(0)x_2(t)\rangle\right|^{1/2}_{\text{max}} \] where \(\langle x_1(0)x_2(t)\rangle\) is the cross - correlation function of the displacements of the two cantilevers. Through these studies, the authors provide theoretical basis and technical support for the future development of highly sensitive biomolecular sensors.